Filtra-Systems Company: OSHA inspections and violations
Gordonsville, Tennessee · All Other Miscellaneous General Purpose Machinery Manufacturing · NAICS 333999
4inspections
35citation items
$9,700current penalties
Aug 18, 2015last inspection
OSHA has inspected Filtra-Systems Company 4 times in Tennessee since 2012.
The latest one began on Aug 18, 2015 on a referral, in Gordonsville.
Those inspections ended with 35 citation items: 18 serious and 17 other-than-serious.
Penalties were first proposed at $11,750 and now stand at $9,700, 17% lower after settlements or reviews.
Noise comes up most often in these citations: 6 items under 1910.95.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Filtra-Systems Company averages $900 (1 cited inspection).
Filtra-Systems Company also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Tennessee · latest 90 days of OSHA records
339employers cited
Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.
OSHA records show Filtra-Systems Company at 3 sites in 3 states. Together they've had 8 inspections and $17,254 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Gordonsville site logged 2 recordable injuries or illnesses among about 45 workers: 4.2 per 100 full-time workers, against a median of 1.9 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Gordonsville Plant
Gordonsville · 2025
45
2
0
4.2
1.9
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(c)(7)
(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location.
(3) The employer shall ensure that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design, or wears eye protection that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses.