OSHA SearchOSHA records by employer

Fin-Tech Inc: OSHA inspections and violations

Houston, Texas · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

5inspections
30citation items
$14,598current penalties
Apr 12, 2018last inspection

Since 1985, OSHA inspectors have visited Fin-Tech Inc in Texas 5 times.

The most recent inspection opened on Apr 12, 2018 as a planned inspection, in Houston.

In all, OSHA issued 30 citation items: 21 serious and 9 other-than-serious.

The proposed penalties came to $22,907; today they stand at $14,598, 36% less.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fin-Tech Inc averages $2,748 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Fin-Tech Inc also files yearly injury logs with OSHA, summarized below.

Fin-Tech Inc: OSHA citation items per year, 1985 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Fin-Tech Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343082368 OPENED APR 12, 2018Closed

Planned · Complete · Safety · 27 employees at the site · Closed Jun 25, 2018

5225 Milwee Street, Houston, TX 77092 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$5,497$2,748May 9, 2018Final

Inspection 109448845 OPENED APR 14, 1993Closed

Planned · Complete · Safety · 25 employees at the site · Closed Aug 31, 1993

5225 Milwee Street, Houston, TX 77092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,000$1,000May 3, 1993Closed
Citation 1, item 1b
29 CFR 1910.22(d)(1) · General requirements
Serious$0$0May 3, 1993Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,000$1,000May 3, 1993Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$2,000$1,500May 3, 1993Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,000$500May 3, 1993Closed
Citation 1, item 5
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$2,000$2,000May 3, 1993Closed
Citation 1, item 6
29 CFR 1910.215(a)(5) · Grinders and abrasive wheels
Serious$1,000$500May 3, 1993Closed
Citation 1, item 7
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,000$500May 3, 1993Closed
Citation 1, item 8
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,000$1,000May 3, 1993Closed
Citation 1, item 9
29 CFR 1910.305(g)(1)(iiib) · Electrical wiring methods
Serious$2,000$1,000May 3, 1993Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$400$400May 3, 1993Closed
Citation 2, item 2
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Other-than-serious$0$0May 3, 1993Closed
Citation 2, item 3
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$0$0May 3, 1993Closed
Citation 2, item 4
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$400$200May 3, 1993Closed

Inspection 100757780 OPENED FEB 19, 1991Closed

Accident · Partial · Safety · 28 employees at the site · Closed Aug 5, 1991

5225 Milwee Street, Houston, TX 77092 · OSHA's record · Phone and website on Google Maps

Incident on Feb 14, 1991 (fatal): Burn - electrical fault in electric grinder

Employee was grinding the inside of a steel pipe with an electric grinder. The g rinder had an internal ground fault that energized its case. The extension cord set for the grinder was connected to a receptacle that had an intermittent groun d because of a loose box and cover. The employee was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$240$240Mar 8, 1991Closed
Citation 1, item 1b
29 CFR 1910.304(e)(1)(via) · Grounding and circuit protection
Serious$0$0Mar 8, 1991Closed
Citation 1, item 2
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$240$240Mar 8, 1991Closed
Citation 1, item 3
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$720$720Mar 8, 1991Closed
Citation 1, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$320$320Mar 8, 1991Closed
Citation 1, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$160$160Mar 8, 1991Closed
Citation 1, item 6
29 CFR 1910.334(b)(2) · Using electrical equipment
Serious$720$360Mar 8, 1991Final

Inspection 106619927 OPENED JAN 24, 1990Closed

Planned · Complete · Safety · 25 employees at the site · Closed Mar 29, 1990

5225 Milwee Street, Houston, TX 77092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$60$60Feb 7, 1990Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$60$60Feb 7, 1990Closed
Citation 1, item 3
29 CFR 1910.243(c)(4) · Guarding of portable powered tools
Serious$90$90Feb 7, 1990Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Feb 7, 1990Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 7, 1990Closed

Inspection 2465805 OPENED APR 4, 1985Closed

Planned · Complete · Health · 19 employees at the site · Closed Jul 12, 1985

5225 Milwee, Houston, TX 77092 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jul 2, 1985Closed
Citation 1, item 3 Other-than-serious$0$0Jul 2, 1985Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Houston site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 3.2 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Fin-Tech, Inc.
Houston · 2017
20 000.03.2

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other electroplating, plating, polishing, anodizing, and coloring employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.