OSHA SearchOSHA records by employer

Fixtur-World, Inc.: OSHA inspections and violations

Cookeville, Tennessee · Wood Office Furniture Manufacturing · NAICS 337211

4inspections
41citation items
$10,225current penalties
Apr 24, 2025last inspection

Since 1996, OSHA inspectors have visited Fixtur-World, Inc. in Tennessee 4 times.

The most recent inspection opened on Apr 24, 2025 after a complaint, in Baxter.

In all, OSHA issued 41 citation items: 29 serious and 12 other-than-serious.

The proposed penalties came to $15,850; today they stand at $10,225, 35% less.

The rule cited most here is 1910.95 (noise), 9 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fixtur-World, Inc. averages $4,600 across 1 cited inspection.

Fixtur-World, Inc.: OSHA citation items per year, 1996 to 2025
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

344employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Fixtur-World, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348203944 OPENED APR 24, 2025Closed

Complaint · Partial · Safety · 69 employees at the site · Closed Jul 2, 2025

455 Ward Mill Road, Baxter, TN 38544 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$1,200$1,200Jun 17, 2025Final
Citation 1, item 2
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$1,400$1,400Jun 17, 2025Final
Citation 1, item 3a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,600$1,600Jun 17, 2025Final
Citation 1, item 3b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jun 17, 2025Final
Citation 1, item 3c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jun 17, 2025Final
Citation 2, item 1
29 CFR TDLWD RULE 800-01-03-.05(1)(A)2
Other-than-serious$400$400Jun 17, 2025Final

Inspection 313927493 OPENED NOV 10, 2009Closed

Complaint · Partial · Health · 175 employees at the site · Closed Mar 4, 2010

1555 Interstate Drive, Cookeville, TN 38501 · Wood Office Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$2,100$1,050Jan 14, 2010Closed
Citation 1, item 1b Serious$0$0Jan 14, 2010Closed
Citation 1, item 1c Serious$0$0Jan 14, 2010Closed
Citation 1, item 1d Serious$0$0Jan 14, 2010Closed
Citation 1, item 1e Serious$0$0Jan 14, 2010Closed
Citation 1, item 1f Serious$0$0Jan 14, 2010Closed
Citation 1, item 1g Serious$0$0Jan 14, 2010Closed
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$1,500$750Jan 14, 2010Closed
Citation 1, item 2b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2c
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2d
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2e
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2f
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2g
29 CFR 1910.107(b)(6) · Spray painting and finishing
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2h
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Jan 14, 2010Closed
Citation 1, item 2i
29 CFR 1910.107(g)(1) · Spray painting and finishing
Serious$0$0Jan 14, 2010Closed
Citation 1, item 3a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$2,400$1,200Jan 14, 2010Closed
Citation 1, item 3b
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Serious$0$0Jan 14, 2010Closed
Citation 1, item 3c
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Jan 14, 2010Closed
Citation 1, item 3d
29 CFR 1910.138(a) · Gloves and hand protection
Serious$0$0Jan 14, 2010Closed
Citation 1, item 4a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$2,100$1,050Jan 14, 2010Closed
Citation 1, item 4b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Jan 14, 2010Closed
Citation 1, item 5
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$2,100$1,050Jan 14, 2010Closed
Citation 2, item 1a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$300$150Jan 14, 2010Closed
Citation 2, item 1b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Jan 14, 2010Closed
Citation 2, item 1c
29 CFR 90007
Other-than-serious$0$0Jan 14, 2010Closed
Citation 2, item 1d
29 CFR 9000602
Other-than-serious$0$0Jan 14, 2010Closed

Inspection 300451994 OPENED FEB 6, 1997Closed

Follow-up · Partial · Health · 120 employees at the site · Closed Feb 10, 1997

1555 Interstate Dr., Cookeville, TN 38501 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300450574 OPENED AUG 20, 1996Closed

Planned · Complete · Health · 120 employees at the site · Closed Feb 27, 1997

1555 Interstate Dr., Cookeville, TN 38501 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1000(e) · Air contaminants
Serious$250$125Oct 14, 1996Closed
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$100$50Oct 14, 1996Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Oct 14, 1996Closed
Citation 2, item 3a Other-than-serious$100$50Oct 14, 1996Closed
Citation 2, item 3b Other-than-serious$0$0Oct 14, 1996Closed
Citation 2, item 4a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$150$75Oct 14, 1996Closed
Citation 2, item 4b
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 14, 1996Closed
Citation 2, item 5
29 CFR 9000609
Other-than-serious$150$75Oct 14, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.95 · Noise

Other wood office furniture manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.