OSHA SearchOSHA records by employer

Fountain Construction Company: OSHA inspections and violations

Daphne, Alabama · Framing Contractors · NAICS 238130

3inspections
12citation items
$12,013current penalties
Apr 6, 2017last inspection

OSHA has inspected Fountain Construction Company 3 times in Alabama since 1999.

The latest one began on Apr 6, 2017 as a planned inspection, in Daphne.

Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.

Penalties were first proposed at $12,013 and still stand at $12,013.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Fountain Construction Company averages $7,063 (1 cited inspection).

Fountain Construction Company: OSHA citation items per year, 1999 to 2017
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

27 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Fountain Construction Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342231024 OPENED APR 6, 2017Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jun 26, 2020

577 Falling Water Blvd. Lot-14, Daphne, AL 36526 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,630$1,630Jun 2, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$3,803Jun 2, 2017Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,630$1,630Jun 2, 2017Final

Inspection 308789825 OPENED AUG 11, 2005Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jul 27, 2010

Lot #2 Tealwood Subdivision, Daphne, AL 36526 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,500Dec 12, 2005Closed
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$750$750Dec 12, 2005Closed
Citation 1, item 2b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Dec 12, 2005Closed
Citation 1, item 2c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Dec 12, 2005Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$1,500Dec 12, 2005Closed
Citation 1, item 4a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$600Dec 12, 2005Closed
Citation 1, item 4b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Dec 12, 2005Closed
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$300$300May 31, 2006Closed
Citation 2, item 2
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$300$300May 31, 2006Closed

Inspection 302322318 OPENED JUL 13, 1999Closed

Unprogrammed other · Complete · Safety · 35 employees at the site · Closed Jul 15, 1999

4605 Airport Road, Gadsden, AL 35904 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.