Since 2008, OSHA inspectors have visited Fox Engineering LLC in Minnesota 4 times.

The most recent inspection opened on Jul 16, 2026 as a planned inspection, in Cambridge.

In all, OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

The proposed penalties came to $4,025; today they stand at $2,675, 34% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Fox Engineering LLC averages $619 across 2 cited inspections.

Fox Engineering LLC: OSHA citation items per year, 2008 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Fox Engineering LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349056903 OPENED JUL 16, 2026Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 15, 2026

1412 317th Avenue Ne, Cambridge, MN 55008 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$450$270Jul 28, 2026Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$450Jul 28, 2026Final
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$600$360Jul 28, 2026Final

Inspection 343014742 OPENED MAR 13, 2018Closed

Planned · Complete · Safety · 6 employees at the site · Closed Apr 6, 2018

1412 317th Avenue Ne, Cambridge, MN 55008 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$225$158Mar 19, 2018Final

Inspection 316574649 OPENED JUN 25, 2012Closed

Planned · Complete · Safety · 11 employees at the site · Closed Aug 13, 2012

1412 317th Avenue Ne, Cambridge, MN 55008 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$675$472Jul 18, 2012Closed
Citation 1, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$225$158Jul 18, 2012Closed
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$375$262Jul 18, 2012Closed
Citation 1, item 4
29 CFR 1910.333(b)(2)(iib) · Working near live electrical parts
Serious$375$262Jul 18, 2012Closed
Citation 1, item 5 Serious$225$158Jul 18, 2012Closed

Inspection 312400443 OPENED JUL 9, 2008Closed

Planned · Complete · Health · 9 employees at the site · Closed Aug 7, 2008

1412 317th Avenue Ne, Cambridge, MN 55008 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$125$125Jul 15, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts