OSHA SearchOSHA records by employer

Francis Metal Works LLC: OSHA inspections and violations

Osseo, Minnesota · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

1inspections
20citation items
$1,500current penalties
Jul 16, 2015last inspection

OSHA has inspected Francis Metal Works LLC once in Minnesota.

The inspection began on Jul 16, 2015 as a planned inspection, in Osseo.

That inspection ended with 20 citation items: 9 serious and 11 other-than-serious.

Penalties were first proposed at $9,000 and now stand at $1,500, 83% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Francis Metal Works LLC averages $1,500 (1 cited inspection).

Francis Metal Works LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

374employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Francis Metal Works LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317996114 OPENED JUL 16, 2015Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 3, 2017

8769 Jefferson Hwy, Osseo, MN 55369 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$250$38Aug 4, 2015Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$500$69Aug 4, 2015Final
Citation 1, item 3
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$500$69Aug 4, 2015Final
Citation 1, item 5
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$375$50Aug 4, 2015Final
Citation 1, item 6
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$875$150Aug 4, 2015Final
Citation 1, item 7
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$625$125Aug 4, 2015Final
Citation 1, item 8
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$750$138Aug 4, 2015Final
Citation 1, item 9
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$375$50Aug 4, 2015Final
Citation 1, item 10
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$500$69Aug 4, 2015Final
Citation 1, item 11
29 CFR 1910.212(a)(4) · Machine guarding
Serious$625$125Aug 4, 2015Final
Citation 1, item 12
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$625$125Aug 4, 2015Final
Citation 1, item 15
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$750$138Aug 4, 2015Final
Citation 1, item 16 Other-than-serious$500$69Aug 4, 2015Final
Citation 1, item 17 Serious$750$138Aug 4, 2015Final
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$250$38Aug 4, 2015Final
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$125$19Aug 4, 2015Final
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$250$38Aug 4, 2015Final
Citation 2, item 4
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$125$19Aug 4, 2015Final
Citation 2, item 5
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$250$38Aug 4, 2015Final
Citation 2, item 6 Other-than-serious$0$0Aug 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 5205.116

29 CFR 5206.700

Other all other miscellaneous fabricated metal product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.