OSHA SearchOSHA records by employer

G. Nelson Electric Motors, Inc.: OSHA inspections and violations

Sylacauga, Alabama · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

1inspections
4citation items
$6,069current penalties
Jan 27, 2016last inspection

OSHA inspectors have visited G. Nelson Electric Motors, Inc. in Alabama one time.

It opened on Jan 27, 2016 on a referral, in Sylacauga.

In all, OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

The proposed penalties came to $10,115; today they stand at $6,069, 40% less.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. G. Nelson Electric Motors, Inc. averages $6,069 across 1 cited inspection.

G. Nelson Electric Motors, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

94employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch G. Nelson Electric Motors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341206753 OPENED JAN 27, 2016Closed

Referral · Partial · Safety · 38 employees at the site · Closed Apr 7, 2016

1218 Sylacauga Fayetteville Highway, Sylacauga, AL 35151 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,570$2,142Mar 9, 2016Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,975$1,785Mar 9, 2016Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,570$2,142Mar 9, 2016Final
Citation 2, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Mar 9, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(3)

(3) Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:

29 CFR 1910.212 · Machine guarding

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.