OSHA SearchOSHA records by employer

Gateway Printing Company, Inc.: OSHA inspections and violations

Breman, Georgia · Commercial Printing (except Screen and Books) · NAICS 323111

2inspections
14citation items
$8,752current penalties
Jul 24, 2018last inspection

Gateway Printing Company, Inc. has 2 OSHA inspections on record in Georgia, the first in 1987.

OSHA's last visit started on Jul 24, 2018 as a planned inspection, in Bremen.

Across those inspections OSHA issued 14 citation items: 4 serious and 10 other-than-serious.

OSHA proposed $14,472 in penalties. After settlements and reviews the total is $8,752, down 40%.

Most often, OSHA cited 1910.106, flammable liquids (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Gateway Printing Company, Inc. averages $8,752 over 1 cited inspection in that time.

Gateway Printing Company, Inc.: OSHA citation items per year, 1987 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

157employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Gateway Printing Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343321626 OPENED JUL 24, 2018Closed

Planned · Partial · Safety · 18 employees at the site · Closed Mar 18, 2021

925 Pacific Ave, Bremen, GA 30110 · Commercial Printing (except Screen and Books) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(5)(vi)(a) · Flammable liquids
Serious$4,546$3,150Jan 23, 2019Final
Citation 1, item 2
29 CFR 1910.106(f)(6) · Flammable liquids
Serious$3,864$2,226Jan 23, 2019Final
Citation 1, item 3
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,789$2,226Jan 23, 2019Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,273$1,150Jan 23, 2019Final
Citation 2, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Jan 23, 2019Final
Citation 2, item 2
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Other-than-serious$0$0Jan 23, 2019Final
Citation 2, item 3
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 23, 2019Final
Citation 2, item 4
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Jan 23, 2019Final
Citation 2, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Jan 23, 2019Final
Citation 2, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 23, 2019Final

Inspection 2168839 OPENED MAR 10, 1987Closed

Complaint · Partial · Health · 35 employees at the site · Closed Jun 9, 1987

913 Pacific Avneue, Breman, GA 30110 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0May 4, 1987Closed
Citation 1, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0May 4, 1987Closed
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 4, 1987Closed
Citation 1, item 4
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0May 4, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.106(d)(5)(vi)(a)

(vi) Flammable liquid warehouses or storage buildings. (a) If the storage building is located 50 feet or less from a building or line of adjoining property that may be built upon, the exposing wall shall be a blank wall having a fire-resistance rating of at least 2 hours.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.305 · Electrical wiring methods

Other commercial printing (except screen and books) employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.