6inspections
23citation items
$6,496current penalties
Nov 7, 2024last inspection

Since 1998, OSHA inspectors have visited Geotex, Inc. in Texas 6 times.

The most recent inspection opened on Nov 7, 2024, in North Richland Hills.

In all, OSHA issued 23 citation items: 18 serious and 5 other-than-serious.

The proposed penalties came to $10,826; today they stand at $6,496, 40% less.

The rule cited most here is 1910.219 (belts, pulleys and power-transmission parts), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Geotex, Inc. averages $2,145 across 2 cited inspections.

Geotex, Inc.: OSHA citation items per year, 1998 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Geotex, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347865933 OPENED NOV 7, 2024Closed

Unprogrammed other · Partial · Health · 9 employees at the site · Closed Jul 2, 2025

6700 Davis Boulevard, North Richland Hills, TX 76182 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,837$1,702Mar 3, 2025Final

Inspection 347901001 OPENED NOV 7, 2024Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed May 13, 2025

6700 Davis Boulevard, North Richland Hills, TX 76182 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,783$2,270Mar 3, 2025Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$531$319Mar 3, 2025Final

Inspection 306204199 OPENED NOV 19, 2003Closed

Planned · Complete · Safety · 18 employees at the site · Closed Dec 17, 2003

6700 Davis Blvd. Ste. A, N. Richland Hills, TX 76180 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$450$270Dec 3, 2003Closed
Citation 1, item 1b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Dec 3, 2003Closed
Citation 1, item 2a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$450$270Dec 3, 2003Closed
Citation 1, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 3, 2003Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$450$270Dec 3, 2003Closed
Citation 1, item 3b
29 CFR 1910.219(e)(2)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 3, 2003Closed
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$450$270Dec 3, 2003Closed
Citation 1, item 5
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$450$270Dec 3, 2003Closed
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Dec 3, 2003Closed
Citation 2, item 2b
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 3, 2003Closed

Inspection 300518552 OPENED JUL 8, 1998Closed

Follow-up · Partial · Health · 15 employees at the site · Closed Jul 8, 1998

6700 Davis Blvd A, Fort Worth, TX 76180 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300516481 OPENED FEB 27, 1998Closed

Planned · Complete · Safety · 15 employees at the site · Closed Apr 7, 1998

6700 Davis Blvd A, Fort Worth, TX 76180 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$225$135Mar 10, 1998Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$300$180Mar 10, 1998Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$300$180Mar 10, 1998Closed
Citation 1, item 3b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 10, 1998Closed
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$300$180Mar 10, 1998Closed

Inspection 300516523 OPENED FEB 27, 1998Closed

Planned · Complete · Health · 15 employees at the site · Closed Jul 8, 1998

6700 Davis Blvd A, Fort Worth, TX 76180 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$300$180Mar 12, 1998Closed
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Mar 12, 1998Closed
Citation 1, item 1c
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Mar 12, 1998Closed
Citation 2, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Mar 12, 1998Closed
Citation 2, item 2
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Mar 12, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise