OSHA SearchOSHA records by employer

Gilster-Mary Lee Corporation: OSHA inspections and violations

Wilson, Arkansas · Perishable Prepared Food Manufacturing · NAICS 311991

7inspections
51citation items
$39,894current penalties
Oct 29, 2019last inspection

Since 1981, OSHA inspectors have visited Gilster-Mary Lee Corporation in Arkansas 7 times.

The most recent inspection opened on Oct 29, 2019 on a referral, in Wilson.

In all, OSHA issued 51 citation items: 22 serious and 29 other-than-serious.

The proposed penalties came to $70,183; today they stand at $39,894, 43% less.

The rule cited most here is 1910.304 (grounding and circuit protection), 9 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,874 penalty. Gilster-Mary Lee Corporation averages $27,349 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Gilster-Mary Lee Corporation also files yearly injury logs with OSHA, summarized below.

It reported 3 severe injuries to OSHA since 2015.

Gilster-Mary Lee Corporation: OSHA citation items per year, 1981 to 2019
Citation items per year, by inspection date.

Arkansas · latest 90 days of OSHA records

16employers cited

Get notified the morning OSHA posts each new citation in Arkansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arkansas

Checking a subcontractor, a client or your own company? Watch Gilster-Mary Lee Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Gilster-Mary Lee Corporation at 12 sites in 3 states. Together they've had 109 inspections and $645,601 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 12 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 344416128 OPENED OCT 29, 2019Closed

Referral · Partial · Safety · 173 employees at the site · Closed Apr 7, 2022

5755 South Us Highway 61, Wilson, AR 72395 · Packaged Frozen Food Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Incident on Oct 22, 2019: Employee amputates finger when caught in auger scooping prod

At 11:00 a.m. on October 22, 2019, an employee working for a frozen food packaging company was dumping a gram into a hopper. The employee was hand scooping the gram inside the hopper when he caught his left hand in the auger. The employee amputated his middle finger and required medical treatment without hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$13,494$6,747Apr 27, 2020Final
Citation 1, item 2b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 27, 2020Final
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$13,494$10,000Apr 27, 2020Final
Citation 1, item 6
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$11,566$5,783Apr 27, 2020Final
Citation 1, item 7
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$9,639$4,819Apr 27, 2020Final

Inspection 314333477 OPENED APR 26, 2010Closed

Accident · Partial · Safety · 119 employees at the site · Closed Sep 8, 2010

5755 Highway 61 South, Wilson, AR 72395 · Perishable Prepared Food Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 22, 2010 (fatal): Employee dies after being crushed in freight elevator

Employee #1 and a coworker had replaced doors on a freight elevator and were rid ing the elevator up to the second floor level to clamp cables on the elevator do or. Employee #1 was standing in the back of the elevator while the coworker was operating the controls. When the coworker heard Employee #1 yell, he turned arou nd to see Employee #1 leaning over the elevator gate with his head pinned betwee n the elevator door and the second floor. The coworker immediately stopped the e levator and lowered the elevator gate. Employee #1 then fell backward onto the f loor and struck his head on a channel iron that was mounted to the floor. He was transported to the hospital, where he died two months later.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,000$3,000Aug 9, 2010Closed
Citation 1, item 2
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,000$3,000Aug 9, 2010Closed

Inspection 107571143 OPENED APR 21, 1992Closed

Planned · Complete · Safety · 109 employees at the site · Closed Jun 30, 1992

Hwy. 61 S., Wilson, AR 72395 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,500$790May 29, 1992Closed
Citation 1, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$1,500$790May 29, 1992Closed
Citation 1, item 3
29 CFR 1910.304(f)(5)(iva) · Grounding and circuit protection
Serious$1,500$790May 29, 1992Closed
Citation 1, item 4
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$1,500$790May 29, 1992Closed
Citation 1, item 5
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$1,500$790May 29, 1992Closed
Citation 1, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$1,500$790May 29, 1992Closed
Citation 1, item 7
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$1,500$780May 29, 1992Closed
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0May 29, 1992Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0May 29, 1992Closed

Inspection 106572472 OPENED AUG 24, 1989Closed

Planned · Complete · Safety · 104 employees at the site · Closed Sep 13, 1989

Hwy. 61 So. 3 Miles, Wilson, AR 72395 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 1, 1989Closed

Inspection 100287879 OPENED MAY 7, 1986Closed

Planned · Complete · Safety · 115 employees at the site · Closed Jul 8, 1986

Hwy. 61 South, Wilson, AR 72395 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$320$160Jun 10, 1986Closed
Citation 1, item 1b
29 CFR 1910.178(m)(12) · Forklifts and other powered industrial trucks
Serious$0$0Jun 10, 1986Closed
Citation 1, item 2
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$240$240Jun 10, 1986Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$80$80Jun 10, 1986Closed
Citation 2, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 6
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 7
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 8
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 9
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Jun 10, 1986Closed
Citation 2, item 11
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 10, 1986Closed

Inspection 16637654 OPENED DEC 1, 1982Closed

Planned · Complete · Safety · 90 employees at the site · Closed Mar 17, 1983

Hwy 61 South, Wilson, AR 72395 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$75Jan 18, 1983Closed
Citation 1, item 2
29 CFR 1910.219(b)(2) · Belts, pulleys and power-transmission parts
Serious$200$60Jan 18, 1983Closed
Citation 1, item 3
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$300$60Jan 18, 1983Closed
Citation 2, item 2
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Dec 22, 1982Closed

Inspection 16591455 OPENED SEP 3, 1981Closed

Planned · Complete · Safety · 92 employees at the site · Closed Nov 6, 1981

Hwy 61 South, Marie, AR 72395 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$150$150Sep 23, 1981Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$200$200Sep 23, 1981Closed
Citation 1, item 2b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 23, 1981Closed
Citation 1, item 2c
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 23, 1981Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 3a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 3b
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 4
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 5
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 6
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 7
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 8
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 9
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 10
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 23, 1981Closed
Citation 2, item 11
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Sep 23, 1981Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2016, the Wilson site logged 5 recordable injuries or illnesses among about 141 workers: 3.4 per 100 full-time workers, against a median of 3.0 for its industry. Those cases cost 24 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Gilster Mary-Lee Wilson Drink Plant
Wilson · 2016
141 523.43.0

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Oct 22, 2019, Wilson: Amputation · amputations · fingertip(s)

An employee was putting grams into a machine. The employee opened the screen and was using the left hand to move the gram when the employee's left middle finger was caught by the moving auger inside the machine, amputating the fingertip.

Nov 12, 2018, Wilson: Hospitalization · fractures · toes(s), toenail(s)

An employee was using an electric hand jack on the mixing floor when the jack backed over his right foot, bending his toes back. His toes broke, requiring surgery.

May 3, 2016, Wilson: Amputation · amputations · fingertip(s)

An employee caught his left little finger on the edges of the bathroom door, amputating the fingertip.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other perishable prepared food manufacturing employers in Arkansas

Alert subscribers get notified of each newly cited employer in Arkansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.