OSHA SearchOSHA records by employer

Gos's Welding Incorporated: OSHA inspections and violations

Ogden, Utah · Fabricated Structural Metal Manufacturing · NAICS 332312

5inspections
30citation items
$5,425current penalties
Oct 21, 2020last inspection

Since 1994, OSHA inspectors have visited Gos's Welding Incorporated in Utah 5 times.

The most recent inspection opened on Oct 21, 2020 after a complaint, in Ogden.

In all, OSHA issued 30 citation items: 15 serious and 15 other-than-serious.

The proposed penalties came to $9,850; today they stand at $5,425, 45% less.

The rule cited most here is 1910.134 (respiratory protection), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Gos's Welding Incorporated averages $1,800 across 1 cited inspection.

Gos's Welding Incorporated: OSHA citation items per year, 1994 to 2020
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Gos's Welding Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344988357 OPENED OCT 21, 2020Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Feb 24, 2021

1673 W 2650 S, Ogden, UT 84401 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR UAC R614-1-5.D.7
Serious$600$300Jan 13, 2021Final
Citation 1, item 2a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,500$750Jan 13, 2021Final
Citation 1, item 2b
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Jan 13, 2021Final
Citation 1, item 3a
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,500$750Jan 13, 2021Final
Citation 1, item 3b
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$0$0Jan 13, 2021Final

Inspection 315872978 OPENED SEP 14, 2011Closed

Complaint · Partial · Health · 16 employees at the site · Closed Jan 10, 2012

1673 W 2650 S, Ogden, UT 84401 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 10005 E11
Serious$375$188Nov 28, 2011Closed
Citation 1, item 2a
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$1,500$750Nov 28, 2011Closed
Citation 1, item 2b
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$0$0Nov 28, 2011Closed
Citation 1, item 2c
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Nov 28, 2011Closed
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$375$188Nov 28, 2011Closed
Citation 1, item 3b
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$0$0Nov 28, 2011Closed
Citation 1, item 4a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$1,500$750Nov 28, 2011Closed
Citation 1, item 4b
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0Nov 28, 2011Closed
Citation 1, item 5
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,500$750Nov 28, 2011Closed

Inspection 126786664 OPENED APR 13, 1998Closed

Planned · Complete · Safety · 14 employees at the site · Closed Apr 13, 1999

1673 West 2650 South, Ogden, UT 84401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Apr 21, 1998Closed
Citation 1, item 2
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Apr 21, 1998Closed
Citation 1, item 3
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Apr 21, 1998Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 21, 1998Closed
Citation 1, item 5
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Apr 21, 1998Closed

Inspection 124632621 OPENED AUG 2, 1994Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed Aug 2, 1994

1673 West 2650 South, Ogden, UT 84401 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124625237 OPENED FEB 15, 1994Closed

Planned · Complete · Safety · 11 employees at the site · Closed Aug 12, 1994

1673 West 2650 South, Ogden, UT 84401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$1,000$1,000Mar 10, 1994Closed
Citation 2, item 1 Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 2
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 3
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 4
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 6
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 7
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 8
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 9
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Mar 10, 1994Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Mar 10, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1010.40

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(c)(7)

(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other fabricated structural metal manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.