3inspections
27citation items
$3,850current penalties
Sep 5, 2017last inspection

GP Fabrication Inc. has 3 OSHA inspections on record in North Carolina, the first in 2005.

OSHA's last visit started on Sep 5, 2017 as a planned inspection, in Reidsville.

Across those inspections OSHA issued 27 citation items: 10 serious and 17 other-than-serious.

OSHA proposed $3,850 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.1200, hazard communication (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. GP Fabrication Inc. averages $1,000 over 1 cited inspection in that time.

GP Fabrication Inc.: OSHA citation items per year, 2005 to 2017
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch GP Fabrication Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342624301 OPENED SEP 5, 2017Closed

Planned · Complete · Health · 11 employees at the site · Closed Dec 1, 2017

9968 Hwy. 158, Reidsville, NC 27320 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$250$250Oct 19, 2017Final
Citation 1, item 2
29 CFR 1910.212(a)(2) · Machine guarding
Serious$250$250Oct 19, 2017Final
Citation 1, item 3a
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$250$250Oct 19, 2017Final
Citation 1, item 3b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Oct 19, 2017Final
Citation 1, item 4a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$250$250Oct 19, 2017Final
Citation 1, item 4b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Oct 19, 2017Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 3
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 5
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 6
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Oct 19, 2017Final
Citation 2, item 7
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Oct 19, 2017Final

Inspection 312194657 OPENED OCT 7, 2008Closed

Planned · Complete · Health · 11 employees at the site · Closed Mar 23, 2012

9968 Hwy. 158, Reidsville, NC 27320 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,050$1,050Oct 17, 2008Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,050$1,050Oct 17, 2008Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 2
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 3
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 5
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 6
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 7
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 8
29 CFR 1910.305(g)(1)(ivb) · Electrical wiring methods
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 17, 2008Closed
Citation 2, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 17, 2008Closed

Inspection 309510121 OPENED NOV 15, 2005Closed

Unprogrammed related · Partial · Health · 30 employees at the site · Closed Jul 18, 2006

168 Industrial Blvd, Mocksville, NC 27028 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.352(a) · Fire prevention
Serious$750$750Apr 18, 2006Closed
Citation 1, item 1b
29 CFR 1926.352(c) · Fire prevention
Serious$0$0Apr 18, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.352 · Fire prevention

29 CFR 9501.2901

Other all other miscellaneous fabricated metal product manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.