Gulf Coast Precast, Inc.: OSHA inspections and violations

E.Fort Myers, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

2inspections
7citation items
$12,543current penalties
Feb 22, 2024last inspection

Since 1999, OSHA inspectors have visited Gulf Coast Precast, Inc. in Florida 2 times.

The most recent inspection opened on Feb 22, 2024, in Ave Maria.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $19,572; today they stand at $12,543, 36% less.

The rule cited most here is 1910.178 (forklifts and other powered industrial trucks), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gulf Coast Precast, Inc. averages $9,043 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Gulf Coast Precast, Inc.: OSHA citation items per year, 1999 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Gulf Coast Precast, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347301640 OPENED FEB 22, 2024Closed

Unprogrammed other · Partial · Safety · 7 employees at the site · Closed Sep 29, 2024

5410 Double Eagle Circle Building 2200, Ave Maria, FL 34142 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$6,452$3,871Jul 2, 2024Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,702$2,821Jul 2, 2024Final
Citation 1, item 3
29 CFR 1926.1431(a) · Hoisting personnel
Serious$3,918$2,351Jul 2, 2024Final

Inspection 302137864 OPENED MAR 29, 1999Closed

Accident · Partial · Safety · 19 employees at the site · Closed Sep 14, 1999

2506 Precast Court, E.fort Myers, FL 33916 · OSHA's record · Phone and website on Google Maps

Incident on Mar 26, 1999 (fatal): Employee struck by precast spreader bar

On March 26, 1999, Employee #1 was placing cribbing down on the ground in prepar ation of storing/stacking precast cement forms. A Toyota 30,000-pound forklift a pproached the storage area with two sections of precast cement attached and susp ended from a spreader bar attachment. As the forks were lowered, the spreader ba r slipped and fell off the forks striking Employee #1. Employee #1 was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,500$1,500Jul 29, 1999Closed
Citation 1, item 2a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$1,500$500Jul 29, 1999Closed
Citation 1, item 2b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Serious$0$0Jul 29, 1999Closed
Citation 1, item 3
29 CFR 1910.178(o)(6) · Forklifts and other powered industrial trucks
Serious$1,500$1,500Jul 29, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(4)

(4) Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.

29 CFR 1910.178(a)(5)

(5) If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered.

29 CFR 1910.178(o)(6)

(6) Extreme care shall be used when tilting the load forward or backward, particularly when high tiering. Tilting forward with load engaging means elevated shall be prohibited except to pick up a load. An elevated load shall not be tilted forward except when the load is in a deposit position over a rack or stack. When stacking or tiering, only enough backward tilt to stabilize the load shall be used.

29 CFR 1926.1431 · Hoisting personnel

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

OSH Act Section 5 · General Duty Clause

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.