OSHA SearchOSHA records by employer

H & S Tool and Engineering, Inc.: OSHA inspections and violations

Fall River, Massachusetts · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912

2inspections
6citation items
$2,200current penalties
Apr 23, 2025last inspection

Since 2006, OSHA inspectors have visited H & S Tool and Engineering, Inc. in Massachusetts 2 times.

The most recent inspection opened on Apr 23, 2025 as a planned inspection, in Fall River.

In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

The proposed penalties came to $4,953; today they stand at $2,200, 56% less.

The rule cited most here is 1910.213 (woodworking machinery), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. H & S Tool and Engineering, Inc. averages $1,000 across 1 cited inspection.

H & S Tool and Engineering, Inc. also files yearly injury logs with OSHA, summarized below.

H & S Tool and Engineering, Inc.: OSHA citation items per year, 2006 to 2025
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

255employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch H & S Tool and Engineering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348199480 OPENED APR 23, 2025Closed

Planned · Complete · Safety · 25 employees at the site · Closed Aug 21, 2025

777 Airport Road, Fall River, MA 02720 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.9(b) · Compliance duties owed to each employee
Other-than-serious$2,553$1,000Jul 10, 2025Final

Inspection 309564243 OPENED FEB 1, 2006Closed

Planned · Partial · Safety · 12 employees at the site · Closed Apr 4, 2006

994 Jefferson Street, Fall River, MA 02701 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.38(b) · Emergency action plans
Serious$450$225Feb 15, 2006Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$300Feb 15, 2006Closed
Citation 1, item 3
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$600$300Feb 15, 2006Closed
Citation 1, item 4a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$750$375Feb 15, 2006Closed
Citation 1, item 4b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Feb 15, 2006Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Fall River site logged 1 recordable injury or illness among about 33 workers: 3.3 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 301 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
H&S Tool and Engineering, Inc.
Fall River · 2025
33 113.32.7

Included with any plan: 2 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.213(h)(4)

(4) Installation shall be in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator.

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.9 · Compliance duties owed to each employee

Other fluid power valve and hose fitting manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.