OSHA SearchOSHA records by employer

Hammond Group Incorporated: OSHA inspections and violations

Hammond, Indiana · Other Basic Inorganic Chemical Manufacturing · NAICS 325188

1inspections
3citation items
$1,925current penalties
Apr 21, 2015last inspection

Hammond Group Incorporated has one OSHA inspection on record in Indiana.

OSHA opened it on Apr 21, 2015 as part of a related case, in Hammond.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $4,950 in penalties. After settlements and reviews the total is $1,925, down 61%.

Most often, OSHA cited 1910.1025, lead in general industry (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Hammond Group Incorporated averages $1,925 over 1 cited inspection in that time.

Hammond Group Incorporated also files yearly injury logs with OSHA, summarized below.

Hammond Group Incorporated: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Hammond Group Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Hammond Group Incorporated at 2 sites in 2 states. Together they've had 7 inspections and $28,181 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 317864858 OPENED APR 21, 2015Closed

Unprogrammed related · Partial · Health · 19 employees at the site · Closed Feb 11, 2016

3100 Michigan Street, Hammond, IN 46323 · Other Basic Inorganic Chemical Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$1,100$0Aug 20, 2015Closed
Citation 1, item 2
29 CFR 1910.1025(d)(5) · Lead in general industry
Serious$1,925$962Aug 20, 2015Closed
Citation 1, item 3
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$1,925$962Aug 20, 2015Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Hammond site logged 1 recordable injury or illness among about 39 workers: 3.9 per 100 full-time workers, against a median of 0.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Hammond Lead Products - Hammond Plant
Hammond · 2025
39 103.90.7
Hammond Expanders
Hammond · 2025
18 000.00.7
Hammond Group, Inc.
Hammond · 2025
12 000.00.0
Hammond Expanders - Osborn Street
Hammond · 2017
14 2122.10.7

Included with any plan: 28 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(5)

(5) Negative initial determination. Where a determination, conducted under paragraphs (d) (2) and (3) of this section is made that no employee is exposed to airborne concentrations of lead at or above the action level, the employer shall make a written record of such determination. The record shall include at least the information specified in paragraph (d)(3) of this section and shall also include the date of determination, location within the worksite, and the name number of each employee monitored.

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

Other other basic inorganic chemical manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.