Inspection 342942117 OPENED FEB 12, 2018Closed
Allied Quarry Rd, Kailua Kona, HI 96740 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Feb 5, 2018 (fatal): Employee fell from trailer and fractured several ribs and la
At 8:00 a.m. on February 5, 2018, an employee was unhooking some rigging from a concrete dry well ring located on a flat rack trailer. The employee fell off the trailer and struck the right side of his body on a forklift outrigger support. The employee fractured several ribs and was hospitalized where he died later.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.25(b)(1)(i) · Stairways |
Serious | $4,346 | $3,694 | Mar 27, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.25(d)(1)(i) · Stairways |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 1c 29 CFR 1910.25(d)(1)(x) · Stairways |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 1d 29 CFR 1910.26(c)(2)(vii) · Dockboards |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $4,346 | $3,694 | Mar 27, 2018 | Final |
| Citation 1, item 3a 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Serious | $2,174 | $1,848 | Mar 27, 2018 | Final |
| Citation 1, item 3b 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 3c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 3d 29 CFR 1910.134(h)(2)(i) · Respiratory protection |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 3e 29 CFR 1910.134(h)(1) · Respiratory protection |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks |
Serious | $3,622 | $3,079 | Mar 27, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks |
Serious | $3,622 | $3,079 | Mar 27, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $3,622 | $3,079 | Mar 27, 2018 | Final |
| Citation 1, item 7 29 CFR 1910.184(e)(1) · Slings |
Serious | $3,622 | $3,079 | Mar 27, 2018 | Final |
| Citation 1, item 8a 29 CFR 1910.184(e)(7)(i) · Slings |
Serious | $3,622 | $3,079 | Mar 27, 2018 | Final |
| Citation 1, item 8b 29 CFR 1910.184(e)(9)(i) · Slings |
Serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 1 29 CFR 12-60-7 |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 2 29 CFR 1904.32(a)(4) · Yearly injury summary |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 3 29 CFR 1910.25(d)(1)(x) · Stairways |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 4 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 5 29 CFR 1910.141(d)(1) · Sanitation |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 6 29 CFR 1910.141(d)(2)(iv) · Sanitation |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 7 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 8 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 9 29 CFR 1910.178(m)(5)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 10 29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 11 29 CFR 1910.213(i)(1) · Woodworking machinery |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 12 29 CFR 1910.254(d)(8) · Arc welding and cutting |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 13 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 14 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |
| Citation 2, item 15 29 CFR 1910.1200(h)(3)(iv) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 27, 2018 | Final |