OSHA SearchOSHA records by employer

Hed Cycling Products Inc: OSHA inspections and violations

Shoreview, Minnesota · Motorcycle, Bicycle, and Parts Manufacturing · NAICS 336991

6inspections
23citation items
$5,675current penalties
Feb 24, 2025last inspection

Hed Cycling Products Inc has 6 OSHA inspections on record in Minnesota, the first in 2009.

OSHA's last visit started on Feb 24, 2025 as a planned inspection, in Saint Paul.

Across those inspections OSHA issued 23 citation items: 9 serious and 14 other-than-serious.

OSHA proposed $6,875 in penalties. After settlements and reviews the total is $5,675, down 17%.

Most often, OSHA cited 5206.700, (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Hed Cycling Products Inc averages $1,750 over 2 cited inspections in that time.

Hed Cycling Products Inc: OSHA citation items per year, 2009 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Hed Cycling Products Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348066184 OPENED FEB 24, 2025Closed

Planned · Complete · Safety · 27 employees at the site · Closed Apr 16, 2025

1735 Terrace Drive, Saint Paul, MN 55113 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$800$480Mar 17, 2025Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$600$360Mar 17, 2025Final
Citation 1, item 3 Serious$600$360Mar 17, 2025Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$200$120Mar 17, 2025Final
Citation 2, item 2
29 CFR 1910.304(b)(4)(ii)(b) · Grounding and circuit protection
Other-than-serious$400$240Mar 17, 2025Final
Citation 2, item 3 Other-than-serious$400$240Mar 17, 2025Final

Inspection 343204954 OPENED JUN 5, 2018Closed

Planned · Complete · Safety · 48 employees at the site · Closed Aug 21, 2018

1735 Terrace Drive, Saint Paul, MN 55113 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$500$500Jun 20, 2018Final
Citation 1, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$500$500Jun 20, 2018Final
Citation 1, item 3
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$400$400Jun 20, 2018Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$200$200Jun 20, 2018Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$100$100Jun 20, 2018Final

Inspection 342530979 OPENED AUG 8, 2017Closed

Complaint · Partial · Health · 48 employees at the site · Closed Dec 13, 2017

1735 Terrace Drive, Saint Paul, MN 55113 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317584688 OPENED FEB 12, 2014Closed

Planned · Complete · Safety · 24 employees at the site · Closed Apr 7, 2014

4643 Chatsworth St N, Shoreview, MN 55126 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$150$150Mar 10, 2014Closed
Citation 1, item 2
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$150$150Mar 10, 2014Closed
Citation 1, item 3 Other-than-serious$150$150Mar 10, 2014Closed

Inspection 317584803 OPENED FEB 12, 2014Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 7, 2014

1025 Tomlyn St, Shoreview, MN 55126 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$450$450Mar 10, 2014Closed
Citation 1, item 2
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$450$450Mar 10, 2014Closed
Citation 2, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$150$150Mar 10, 2014Closed
Citation 2, item 2
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$150$150Mar 10, 2014Closed
Citation 2, item 3 Other-than-serious$150$150Mar 10, 2014Closed

Inspection 313731978 OPENED SEP 9, 2009Closed

Planned · Complete · Health · 18 employees at the site · Closed Oct 26, 2009

4643 Chatsworth St N, Shoreview, MN 55126 · Motorcycle, Bicycle, and Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Sep 23, 2009Closed
Citation 2, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$250$250Sep 23, 2009Closed
Citation 2, item 2 Other-than-serious$125$125Sep 23, 2009Closed
Citation 2, item 3 Other-than-serious$0$0Sep 23, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(3)(iv)

(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 5205.116

29 CFR 5205.880

29 CFR 5206.700

Other motorcycle, bicycle, and parts manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.