OSHA SearchOSHA records by employer

Henock Construction, LLC: OSHA inspections and violations

San Antonio, Texas · Residential Remodelers · NAICS 236118

1inspections
10citation items
$13,850current penalties
Mar 31, 2025last inspection

Henock Construction, LLC has one OSHA inspection on record in Texas.

OSHA opened it on Mar 31, 2025 after a complaint, in San Antonio.

From that inspection OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

OSHA proposed $20,605 in penalties. After settlements and reviews the total is $13,850, down 33%.

Most often, OSHA cited 1910.107, spray painting and finishing (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Henock Construction, LLC averages $13,850 over 1 cited inspection in that time.

Henock Construction, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Henock Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348146002 OPENED MAR 31, 2025Closed

Complaint · Partial · Health · 13 employees at the site · Closed Sep 14, 2026

1423 East Houston Street, San Antonio, TX 78202 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$5,296$2,600Aug 4, 2025Final
Citation 1, item 2a Serious$6,621$3,200Aug 4, 2025Final
Citation 1, item 2b Serious$0$0Aug 4, 2025Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Aug 4, 2025Final
Citation 1, item 4b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$3,900Aug 4, 2025Final
Citation 1, item 4c
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Aug 4, 2025Final
Citation 1, item 4d
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Aug 4, 2025Final
Citation 1, item 5
29 CFR 1910.134(c) · Respiratory protection
Serious$3,972$1,900Aug 4, 2025Final
Citation 1, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,972$1,900Aug 4, 2025Final
Citation 2, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$744$350Aug 4, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

Other residential remodelers employers in Texas