Inspection 344366257 OPENED SEP 26, 2019Closed
4751 Sunset Blvd, Lexington, SC 29072 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Columbia, South Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
Hinds Electric Company Inc has 26 OSHA inspections on record in South Carolina, the first in 1984.
OSHA's last visit started on Sep 26, 2019, in Lexington.
Across those inspections OSHA issued 38 citation items: 19 serious and 19 other-than-serious.
OSHA proposed $3,515 in penalties. After settlements and reviews the total is $2,229, down 37%.
Most often, OSHA cited 1926.405, job-site wiring (12 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Hinds Electric Company Inc averages $150 over 2 cited inspections in that time.
South Carolina · latest 90 days of OSHA records
45employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Hinds Electric Company Inc and get notified the morning OSHA posts a new citation for it.
Watch this company4751 Sunset Blvd, Lexington, SC 29072 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7399 Northwoods Blvd, North Charleston, SC 29406 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $200 | $200 | Dec 29, 2017 | Final |
1615 Gervais St, Columbia, SC 29201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring |
Serious | $100 | $100 | Mar 29, 2016 | Final |
1001 Saxa Gotha Extension, West Columbia, SC 29170 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $100 | $100 | Sep 23, 2010 | Closed |
1400 Main St., Columbia, SC 29201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $100 | $100 | Oct 6, 2006 | Closed |
| Citation 2, item 1 29 CFR 1926.405(a)(2)(iie) · Job-site wiring |
Other-than-serious | $0 | $0 | Oct 6, 2006 | Closed |
2025 Main St., Columbia, SC 29201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $0 | $0 | Oct 20, 2003 | Closed |
2245 Airport Blvd., Cayce, SC 29169 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 30, 2003 | Closed |
1151 Billings Dr, South Middle Sch, Lancaster, SC 29720 · OSHA's record · Phone and website on Google Maps
Incident on Jul 23, 2001: Burn - electrical fault in power panel
A lead electrician was installing a new fuse in a 12,000-amp, 3-phase, 480-volt main power panel during a live switchover. He was bolting a breaker into an exis ting panel board to feed a gymnasium, when he dropped a bolt or screw inside the panel. The fastener landed on a busbar, causing an arc flash fire. The electric ian sustained second-degree burns to his upper torso and third-degree burns to h is hands. He was hospitalized.
No citations from this inspection.
501 Taylor Street, Columbia, SC 29201 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
750 Jamil Road, Columbia, SC 29220 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 4, item 1 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $0 | $0 | Jun 5, 2001 | Closed |
501 Taylor Street, Columbia, SC 29201 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $150 | $150 | May 8, 2001 | Closed |
| Citation 2, item 2a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $375 | $375 | May 8, 2001 | Closed |
| Citation 2, item 2b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | May 8, 2001 | Closed |
| Citation 3, item 1 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Other-than-serious | $0 | $0 | May 8, 2001 | Closed |
| Citation 3, item 2 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Other-than-serious | $0 | $0 | May 8, 2001 | Closed |
101 London St., Blacksburg, SC 29702 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(d) · Job-site wiring |
Serious | $200 | $200 | Nov 16, 2000 | Closed |
2510 Broad St. Ext., Sumter, SC 29150 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $0 | $0 | Jul 19, 1999 | Closed |
220 East Exchange Blvd., Columbia, SC 29209 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $0 | $0 | Nov 4, 1998 | Closed |
136 Wood Olive Ln., Cordova, SC 29039 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $225 | $225 | Jan 10, 1995 | Closed |
| Citation 2, item 1 29 CFR 1926.405(a)(2)(iie) · Job-site wiring |
Other-than-serious | $0 | $0 | Jan 10, 1995 | Closed |
1401 Leaphart St., West Columbia, SC 29169 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Carlisle St., Lake City, SC 29560 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1401 Leaphart St., West Columbia, SC 29169 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1105 N. Lafayette St., Sumter, SC 29150 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements |
Serious | $875 | $350 | Oct 12, 1992 | Closed |
| Citation 1, item 2a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $500 | $200 | Oct 12, 1992 | Closed |
| Citation 1, item 2b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | Oct 12, 1992 | Closed |
| Citation 2, item 1 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Other-than-serious | $0 | $0 | Oct 12, 1992 | Closed |
| Citation 2, item 2 29 CFR 1926.1051(a) · Stairways and Ladders: general requirements |
Other-than-serious | $0 | $0 | Oct 12, 1992 | Closed |
Fifth Ave., Clinton, SC 29325 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2308 S. Irby St., Florence, SC 29501 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | May 4, 1992 | Closed |
795 Pine Log Road, Aiken, SC 29805 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.450(a)(1) · Scope, application and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Mar 14, 1990 | Closed |
795 Pine Log Road, Aiken, SC 29805 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 50002 A |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 2 29 CFR 1926.50(c) · Medical services and first aid |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 3 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 4 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 5 29 CFR 1926.59(e)(2) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 6 29 CFR 1926.59(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
| Citation 1, item 7 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 14, 1989 | Closed |
1513 Roberts Street, Camden, SC 29020 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Other-than-serious | $0 | $0 | Aug 12, 1988 | Closed |
2101 Main St., Columbia, SC 29203 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $490 | $163 | Oct 9, 1987 | Final |
| Citation 1, item 1b 29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart |
Serious | $0 | $0 | Oct 9, 1987 | Final |
| Citation 2, item 1 29 CFR 30006 |
Other-than-serious | $0 | $0 | Oct 9, 1987 | Final |
1905 Green Street, Columbia, SC 29205 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.401(c) · [Reserved] |
Serious | $200 | $66 | Oct 19, 1984 | Final |
| Citation 2, item 1 29 CFR 1926.150(c)(1)(i) · Fire protection |
Other-than-serious | $0 | $0 | Oct 19, 1984 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1926.1051(a)
(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.
29 CFR 1926.150(c)(1)(i)
(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.