OSHA SearchOSHA records by employer

Rapid Rooter LLC: OSHA inspections and violations

Murrells Inlet, South Carolina · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
2citation items
$3,000current penalties
Jul 22, 2026last inspection

OSHA has inspected Rapid Rooter LLC 2 times in South Carolina since 2024.

The latest one began on Jul 22, 2026 to follow up on an earlier case, in Murrells Inlet; the case is still open.

Those inspections ended with 2 citation items: 2 serious.

Penalties were first proposed at $3,000 and still stand at $3,000.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Rapid Rooter LLC averages $3,000 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Rapid Rooter LLC: OSHA citation items per year, 2024 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Rapid Rooter LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349067041 OPENED JUL 22, 2026Open

Follow-up · Partial · Safety · 3 employees at the site · Open

832 Underwood Drive, Murrells Inlet, SC 29576 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 347708950 OPENED AUG 19, 2024Open

Fatality or catastrophe · Partial · Safety · 2 employees at the site · Open

832 Underwood Drive, Murrells Inlet, SC 29576 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 15, 2024 (fatal): Employee is killed when electrocuted while operating drain c

At 12:00 a.m. on August 15, 2024, Employee #1 was working alone at a residential property, performing drain cleaning services using a pipe cleaning snake auger. The owner of Rapid Rooter attempted to contact Employee #1 multiple times throughout the day without success. Upon arriving at the site, the owner found the drain snake running and Employee #1 lying under the home in an area with standing water. Employee #1 died from electrocution while operating the drain snake, which had a missing ground pin.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(6)(vi)(c)(5) · Grounding and circuit protection
Serious$1,500$1,500Jan 23, 2025Final
Citation 1, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$1,500$1,500Jan 23, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.304(g)(6)(vi)(c)(5)

(C) If the equipment is of the following types:

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

Other plumbing, heating, and air-conditioning contractors employers in South Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.