Inspection 349072868 OPENED JUL 22, 2026Open
211 Puckett Ferry Road, Greenwood, SC 29649 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Anderson, South Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
Since 1987, OSHA inspectors have visited Hill Electric Co Inc in South Carolina 21 times.
The most recent inspection opened on Jul 22, 2026 as part of a related case, in Greenwood and is still open.
In all, OSHA issued 22 citation items: 6 serious and 16 other-than-serious.
The proposed penalties came to $6,800; today they stand at $3,425, 50% less.
The rule cited most here is 1926.59 (hazard communication), 7 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Hill Electric Co Inc averages $2,125 across 1 cited inspection.
1 inspection on this page followed a fatal incident.
Hill Electric Co Inc also files yearly injury logs with OSHA, summarized below.
South Carolina · latest 90 days of OSHA records
42employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Hill Electric Co Inc and get notified the morning OSHA posts a new citation for it.
Watch this company211 Puckett Ferry Road, Greenwood, SC 29649 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
15545 Wells Hwy, Seneca, SC 29678 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1910.333(a)(1) · Working near live electrical parts |
Serious | $2,500 | $1,250 | Jan 12, 2018 | Final |
| Citation 1, item 3b 29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection |
Serious | $1,250 | $0 | Jan 12, 2018 | Final |
| Citation 2, item 1 29 CFR 3.39(A) |
Other-than-serious | $1,750 | $875 | Jan 12, 2018 | Final |
2901 New Pond Road, Anderson, SC 29624 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
151 E Church St, Anderson, SC 29624 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $450 | $450 | Jun 16, 2010 | Closed |
15545 Wells Hwy, Seneca, SC 29678 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.334(a)(3)(i) · Using electrical equipment |
Serious | $150 | $150 | Jul 6, 2009 | Closed |
1000 International Drive, Spartanburg, SC 29303 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
103 Clemson Research Blvd, Anderson, SC 29625 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy 76 Clemson Blvd, Sandy Springs, SC 29677 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy 76 Clemson Blvd, Sandy Springs, SC 29677 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1372 N. Old Laurens Road, Fountain Inn, SC 29644 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1000 International Drive, Spartanburg, SC 29303 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1920 Perimeter Rd, Greenville, SC 29605 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Apr 5, 2002 | Closed |
155 Academy Street, Greenwood, SC 29646 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $400 | $400 | Jun 1, 2000 | Closed |
Hwy 93, Easley, SC 29640 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $300 | $300 | May 1, 1998 | Closed |
2017 East River St., Anderson, SC 29622 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Hwy. 28 Industrial Park, Abbeville, SC 29620 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2120 N. Greenville St., Anderson, SC 29621 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Sep 30, 1993 | Closed |
703 Hampton Rd., Williamston, SC 29697 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.1052(c)(1) · Stairways in construction |
Other-than-serious | $0 | $0 | Dec 15, 1992 | Closed |
Hwy. 72 W., Abbeville, SC 29620 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.59(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 2 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 3 29 CFR 1926.59(e)(2) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 4 29 CFR 1926.59(g)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 5 29 CFR 1926.59(h) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 6 29 CFR 1926.500(e)(1)(iv) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 1, item 7 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 2, item 2 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
| Citation 2, item 3 29 CFR 1926.59(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | May 16, 1990 | Closed |
316 Boulevard Ave., Anderson, SC 29621 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1 29 CFR 1926.500(e)(1)(iv) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Jun 8, 1988 | Closed |
Jackson Street, Barnwell, SC 29812 · OSHA's record · Phone and website on Google Maps
Incident on Sep 3, 1987 (fatal): Electric shock - miswired attachment plug
AN ELECTRICIAN HAD REPLACED THE ATTACHMENT PLUG FOR THE POWER SUPPLY CORD ON A M ILLER DIAL ARC 250 AC/DC WELDER. THE CORD CONTAINED ONLY THREE CONDUCTORS: ONE B LUE AND ONE ORANGE CONDUCTOR, WHICH HE CONNECTED TO THE TWO CURRENT CARRYING PIN S ON THE PLUG, AND ONE "BARE" ONE, WHICH HE CONNECTED TO THE GROUNDING PIN. SHOR TLY, AFTER THE REPAIR, A WELDER TURNED ON THE WELDING MACHINE TO PERFORM SOME WO RK. WHEN THE WELDER ATTEMPTED TO ATTACH THE GROUND LEAD, HE RECEIVED AN ELECTRIC SHOCK. HE CALLED THE ELECTRICIAN TO TURN THE MACHINE OFF. THE ELECTRICIAN WAS E LECTROCUTED WHEN HE CONTACTED THE FRAME OF THE WELDING MACHINE. AN INSPECTION OF THE INTERNAL WIRING OF THE WELDING MACHINE SHOWED THAT THE ORANGE CONDUCTOR WAS CONNECTED TO THE CHASSIS OF THE MACHINE AND THAT THE BLUE AND "BLACK" CONDUCTOR S WERE THE CURRENT CARRYING CONDUCTORS. THUS, THE ELECTRICIAN HAD CONNECTED THE EQUIPMENT GROUNDING CONDUCTOR DIRECTLY TO AN ENERGIZED LINE.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Oct 13, 1987 | Final |
| Citation 1, item 1b 29 CFR 1926.404(a)(1) · Ground-fault protection on job sites |
Other-than-serious | $0 | $0 | Oct 13, 1987 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Anderson site logged 0 recordable injuries or illnesses among about 79 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Hill Electric Company Anderson · 2025 | 79 | 0 | 0 | 0.0 | 1.8 |
| Hill Electric Company, Inc. Anderson · 2016 | 85 | 1 | 0 | 0.9 | 1.8 |
Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(6)(ii)
(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
29 CFR 1910.333(a)(1)
(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.
29 CFR 1910.334(a)(3)(i)
(3) Grounding-type equipment. (i) A flexible cord used with grounding-type equipment shall contain an equipment grounding conductor.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.