OSHA SearchOSHA records by employer

Independence Lumber Inc.: OSHA inspections and violations

Independence, Virginia · Sawmills · NAICS 321113

17inspections
146citation items
$217,338current penalties
Mar 16, 2020last inspection

Independence Lumber Inc. has 17 OSHA inspections on record in Virginia, the first in 1986.

OSHA's last visit started on Mar 16, 2020 on a referral, in Independence.

Across those inspections OSHA issued 146 citation items: 126 serious, 2 repeat and 18 other-than-serious.

OSHA proposed $368,962 in penalties. After settlements and reviews the total is $217,338, down 41%.

Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (17 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Independence Lumber Inc. averages $50,555 over 4 cited inspections in that time.

1 inspection on this page followed a fatal incident.

Independence Lumber Inc.: OSHA citation items per year, 1986 to 2020
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Independence Lumber Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344696471 OPENED MAR 16, 2020Closed

Referral · Partial · Safety · 135 employees at the site · Closed Jun 28, 2021

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

Incident on Mar 12, 2020: Employee amputates fingertips in machine

At 9:30 a.m. on March 12, 2020, an employee was preparing to disconnect power to a machine. A coworker turned on the machine to move lumber. The employee amputated three fingertips and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$11,025$6,615Apr 30, 2020Final
Citation 1, item 1b
29 CFR 1910.147(c)(9) · Lockout/tagout
Serious$0$0Apr 30, 2020Final
Citation 1, item 2
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$13,047$13,047Apr 30, 2020Final

Inspection 342838604 OPENED OCT 13, 2017Closed

Follow-up · Partial · Safety · 170 employees at the site · Closed Dec 27, 2017

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341652832 OPENED JUL 28, 2016Closed

Referral · Partial · Health · 130 employees at the site · Closed Mar 20, 2017

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$4,095$2,866Jan 20, 2017Final
Citation 2, item 2
29 CFR 1910.1025(d)(2) · Lead in general industry
Other-than-serious$0$0Jan 20, 2017Final
Citation 2, item 3
29 CFR 1910.1025(l)(1)(i) · Lead in general industry
Other-than-serious$0$0Jan 20, 2017Final

Inspection 341578342 OPENED JUN 21, 2016Open

Planned · Complete · Safety · 135 employees at the site · Open

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 2
29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 3
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 4
29 CFR 1910.27(b)(1)(ii) · Fixed ladders
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 6
29 CFR 1910.27(f) · Fixed ladders
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 7a
29 CFR 1910.36(g)(4) · Exit route design
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 7b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Dec 7, 2016Final
Citation 1, item 8a
29 CFR 1910.37(b)(2) · Exit routes
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 8b
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Dec 7, 2016Final
Citation 1, item 8c
29 CFR 1910.37(b)(6) · Exit routes
Serious$0$0Dec 7, 2016Final
Citation 1, item 9a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 9b
29 CFR 1910.132(e) · Personal protective equipment, general requirements
Serious$0$0Dec 7, 2016Final
Citation 1, item 10
29 CFR 1910.136(a) · Foot protection
Serious$3,990$1,995Dec 7, 2016Final
Citation 1, item 11
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 12a
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 12b
29 CFR 1910.146(d)(3) · Permit-required confined spaces
Serious$0$0Dec 7, 2016Final
Citation 1, item 13
29 CFR 1910.146(c)(5)(ii)(c) · Permit-required confined spaces
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 14
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 15
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 16a
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 16b Serious$0$0Dec 7, 2016Final
Citation 1, item 17
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 18a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 18b
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Serious$0$0Dec 7, 2016Final
Citation 1, item 18c
29 CFR 1910.147(c)(7)(i)(c) · Lockout/tagout
Serious$0$0Dec 7, 2016Final
Citation 1, item 19a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 19b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0Dec 7, 2016Final
Citation 1, item 19c
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Serious$0$0Dec 7, 2016Final
Citation 1, item 20a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 20b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Serious$0$0Dec 7, 2016Final
Citation 1, item 21
29 CFR 1910.178(k)(1) · Forklifts and other powered industrial trucks
Serious$3,360$1,005Dec 7, 2016Final
Citation 1, item 22a
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Serious$3,360$1,080Dec 7, 2016Final
Citation 1, item 22b
29 CFR 1910.178(m)(5)(ii) · Forklifts and other powered industrial trucks
Serious$0$0Dec 7, 2016Final
Citation 1, item 23
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$3,360$1,205Dec 7, 2016Final
Citation 1, item 24
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,410$1,205Dec 7, 2016Final
Citation 1, item 25
29 CFR 1910.212(a)(5) · Machine guarding
Serious$4,410$1,205Dec 7, 2016Final
Citation 1, item 26
29 CFR 1910.212(b) · Machine guarding
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 27
29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts
Serious$4,410$1,205Dec 7, 2016Final
Citation 1, item 28
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 29
29 CFR 1910.219(c)(4)(ii) · Belts, pulleys and power-transmission parts
Serious$4,410$1,775Dec 7, 2016Final
Citation 1, item 30
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 31
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 32
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 33 Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 34 Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 35 Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 36 Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 37 Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 38 Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 39 Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 40 Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 41
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 42
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 43a
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,310$1,155Dec 7, 2016Final
Citation 1, item 43b
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Dec 7, 2016Final
Citation 1, item 44
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 45
29 CFR 1910.304(e)(1)(i) · Grounding and circuit protection
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 46
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 47
29 CFR 1910.305(a)(2)(ii) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 48
29 CFR 1910.305(a)(2)(v)(c) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 49
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Serious$3,360$1,680Dec 7, 2016Final
Citation 1, item 50
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 51
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 52
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 53
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 54
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 55
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 56
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 57
29 CFR 1910.305(j)(1)(iv) · Electrical wiring methods
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 58
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 59
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$4,900$2,450Dec 7, 2016Final
Citation 1, item 60
29 CFR 16VAC25-97-30.A.1
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 61
29 CFR 16VAC25-97-50.A
Serious$4,410$2,205Dec 7, 2016Final
Citation 1, item 62
29 CFR 16VAC25-60-120
Serious$4,410$2,205Dec 7, 2016Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 7, 2016Final
Citation 2, item 2
29 CFR 1910.23(e)(6) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 7, 2016Final

Inspection 341556025 OPENED JUN 15, 2016Open

Fatality or catastrophe · Partial · Safety · 135 employees at the site · Open

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

Incident on Jun 15, 2016 (fatal): Employee is killed when struck and run over by loader.

At approximately 3:00 p.m. on June 15, 2016, an employee was walking down a dirt road. He was struck by a loader and subsequently caught under its front tire, which fractured his skull. The employee was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 3
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 4
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 5 Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 6 Serious$7,000$7,000Dec 7, 2016Final
Citation 1, item 7
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 8
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 9
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 10
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$4,410$4,410Dec 7, 2016Final
Citation 1, item 11
29 CFR 40.1-51.1.A
Serious$7,000$7,000Dec 7, 2016Final

Inspection 340052562 OPENED OCT 21, 2014Closed

Other · Partial · Health · 75 employees at the site · Closed Jan 20, 2015

407 Lumber Lane, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312113376 OPENED APR 7, 2008Closed

Unprogrammed other · Partial · Health · 162 employees at the site · Closed Nov 24, 2008

Old Osborne Hotel, Main Street, Independence, VA 24348 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1101(f)(2) · Asbestos in construction
Serious$2,750$1,375Sep 18, 2008Closed
Citation 1, item 1b
29 CFR 1926.1101(k)(2)(i) · Asbestos in construction
Serious$0$0Sep 18, 2008Closed
Citation 1, item 2
29 CFR 1926.1101(f)(2)(i) · Asbestos in construction
Serious$2,750$1,375Sep 18, 2008Closed
Citation 1, item 3
29 CFR 1926.1101(l)(2) · Asbestos in construction
Serious$2,750$1,375Sep 18, 2008Closed

Inspection 310897061 OPENED FEB 28, 2007Closed

Planned · Complete · Safety · 75 employees at the site · Closed Apr 26, 2007

407 Lumber Lane, Independence, VA 24348 · Cut Stock, Resawing Lumber, and Planing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$1,375$700Apr 9, 2007Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,375$700Apr 9, 2007Closed
Citation 1, item 3
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Serious$1,375$700Apr 9, 2007Closed
Citation 1, item 4
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,375$700Apr 9, 2007Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,375$700Apr 9, 2007Closed
Citation 1, item 6
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$825$700Apr 9, 2007Closed
Citation 1, item 7a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$825$700Apr 9, 2007Closed
Citation 1, item 7b
29 CFR 1910.303(g)(1)(iv) · Electrical equipment, general requirements
Serious$0$0Apr 9, 2007Closed
Citation 1, item 8a
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$825$710Apr 9, 2007Closed
Citation 1, item 8b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Apr 9, 2007Closed
9 older inspections

Inspection 303904007 OPENED MAR 15, 2001Closed

Planned · Complete · Safety · 72 employees at the site · Closed Mar 15, 2001

407 Lumber Lane, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303090476 OPENED SEP 27, 1999Closed

Planned · No inspection · Safety · 60 employees at the site · Closed Sep 27, 1999

Rt. 3, Box 223, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301801239 OPENED DEC 21, 1998Closed

Planned · Complete · Health · 60 employees at the site · Closed May 10, 1999

Rt. 58 W, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$625$625Jan 26, 1999Closed
Citation 1, item 1b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 26, 1999Closed

Inspection 301800025 OPENED DEC 2, 1997Closed

Planned · Partial · Safety · 60 employees at the site · Closed Dec 2, 1997

Rt. 58 W, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 112364260 OPENED FEB 14, 1992Closed

Follow-up · Complete · Safety · 14 employees at the site · Closed Feb 14, 1992

Rt. 58 West, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 112396379 OPENED NOV 27, 1991Closed

Planned · Complete · Safety · 30 employees at the site · Closed Jan 28, 1993

Rt. #58, Main St., Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$240$180Dec 24, 1991Closed
Citation 1, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$400$300Dec 24, 1991Closed
Citation 1, item 3
29 CFR 1910.136 · Foot protection
Serious$640$320Dec 24, 1991Closed
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$400$300Dec 24, 1991Closed
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$400$300Dec 24, 1991Closed
Citation 1, item 6
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$400$300Dec 24, 1991Closed
Citation 1, item 7
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Serious$400$250Dec 24, 1991Closed
Citation 1, item 8
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Serious$400$250Dec 24, 1991Closed
Citation 1, item 9
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$400$300Dec 24, 1991Closed
Citation 1, item 10
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$400$300Dec 24, 1991Closed
Citation 2, item 2
29 CFR 1910.305(b)(2) · Electrical wiring methods
Repeat$960$720Dec 24, 1991Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$480$240Dec 24, 1991Closed
Citation 3, item 1
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Dec 24, 1991Closed
Citation 3, item 2
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Dec 24, 1991Closed

Inspection 105674584 OPENED FEB 7, 1989Closed

Planned · Complete · Safety · 22 employees at the site · Closed May 2, 1989

Rt. #58, Main Street, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(c) · General requirements
Serious$250$250Feb 28, 1989Closed
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$100$100Feb 28, 1989Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$100$100Feb 28, 1989Closed
Citation 1, item 4a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$100$100Feb 28, 1989Closed
Citation 1, item 4b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Feb 28, 1989Closed
Citation 1, item 4c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Feb 28, 1989Closed
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$250$250Feb 28, 1989Closed
Citation 1, item 5b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Feb 28, 1989Closed
Citation 1, item 5c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Feb 28, 1989Closed
Citation 1, item 6
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$100$100Feb 28, 1989Closed
Citation 1, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$100$100Feb 28, 1989Closed
Citation 2, item 1
29 CFR ARM001101 A
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 2
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 3
29 CFR 1910.23(a)(9) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 4 Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 5
29 CFR 1910.252(a)(2)(iv)(c) · Welding fire safety
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 7
29 CFR 1910.1200(d)(1) · Hazard communication
Other-than-serious$0$0Feb 28, 1989Closed
Citation 2, item 8
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Feb 28, 1989Closed

Inspection 17376047 OPENED JUL 15, 1986Closed

Planned · Partial · Safety · 13 employees at the site · Closed Aug 18, 1986

Highway 58, Independence, VA 24348 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 23, 1986Closed
Citation 1, item 1b
29 CFR 1910.1200(f)(4) · Hazard communication
Other-than-serious$0$0Jul 23, 1986Closed
Citation 1, item 1c
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jul 23, 1986Closed
Citation 1, item 1d
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jul 23, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.1025(l)(1)(i)

(l) Employee information and training—(1) Training program. (i) Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.136 · Foot protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.265 · Sawmills

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other sawmills employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.