Independence Tube Corporation: OSHA inspections and violations
Decatur, Alabama · Fabricated Structural Metal Manufacturing · NAICS 332312
5inspections
11citation items
$32,065current penalties
Feb 20, 2018last inspection
Since 2009, OSHA inspectors have visited Independence Tube Corporation in Alabama 5 times.
The most recent inspection opened on Feb 20, 2018 on a referral, in Trinity.
In all, OSHA issued 11 citation items: 9 serious and 2 other-than-serious.
The proposed penalties came to $43,753; today they stand at $32,065, 27% less.
The rule cited most here is 1910.147 (lockout/tagout), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Independence Tube Corporation averages $7,763 across 3 cited inspections.
1 inspection on this page followed a fatal incident.
Independence Tube Corporation also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
Citation items per year, by inspection date.
Alabama · latest 90 days of OSHA records
97employers cited
Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Independence Tube Corporation and get notified the morning OSHA posts a new citation for it.
Incident on Feb 9, 2018: Employee catches fingers between two jammed pipes and partia
At 9:00 a.m. on February 9, 2018, an employee was cutting metal pipes when the conveyor jammed. The employee tried to pull out two pipes that were jammed and caught his left ring finger between them. The employee partially amputated his left ring finger and was hospitalized.
Incident on Oct 28, 2015 (fatal): Worker is crushed and killed by falling steel coil.
At 4:00 a.m. on October 28, 2015, a worker was affixing a radial band (belly band) around four steel coils that each measured 7 inches wide by 6 feet in diameter, weighing 6,695 pounds. The coils were located on a coil car, which one of the coils fell off and struck the worker. The worker's abdomen and chest became pinned to the ground, causing severe injury that included a crushed chest, abdomen and left arm, as well as partial amputation of his right arm and fractures to his left leg. The worker died as a result.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Decatur site logged 2 recordable injuries or illnesses among about 97 workers: 1.8 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 257 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Independence Tube Decatur
Decatur · 2019
97
2
2
1.8
3.6
Independence Tube Trinity
Trinity · 2019
90
4
0
4.0
3.6
Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
On September 7, 2018, at about 6:15 a.m., an employee was using a forklift to empty a trash hopper when the hopper shifted. The employee's middle finger was then caught between the hopper and the forks of the forklift, resulting in a medical amputation of the fingertip.
An employee was aligning a steel tube on a conveyor when another tube bumped into the tube he was holding, causing his finger to become caught between the tube and lifting arm of the conveyor. His left ring finger was crushed, resulting in an amputation.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.132 · Personal protective equipment, general requirements
29 CFR 1910.132(a)
(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)(b)
(B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;
Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.