OSHA SearchOSHA records by employer

Industrial Door Contractors Inc: OSHA inspections and violations

Columbia, Tennessee · Metal Window and Door Manufacturing · NAICS 332321

9inspections
75citation items
$22,877current penalties
Aug 3, 2022last inspection

OSHA has inspected Industrial Door Contractors Inc 9 times in Tennessee since 1993.

The latest one began on Aug 3, 2022 after a complaint, in Columbia.

Those inspections ended with 75 citation items: 53 serious and 22 other-than-serious.

Penalties were first proposed at $24,800 and now stand at $22,877, 8% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 16 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Industrial Door Contractors Inc averages $4,470 (2 cited inspections).

1 inspection on this page followed a fatal incident.

Industrial Door Contractors Inc: OSHA citation items per year, 1993 to 2022
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

318employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Industrial Door Contractors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346120942 OPENED AUG 3, 2022Closed

Complaint · Partial · Health · 30 employees at the site · Closed Jan 3, 2023

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Other-than-serious$100$100Dec 9, 2022Final

Inspection 343866075 OPENED MAR 20, 2019Closed

Planned · Complete · Safety · 40 employees at the site · Closed Sep 24, 2019

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR TCA 50-3-105(1)
Serious$1,600$1,360Jun 14, 2019Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,000$3,400Jun 14, 2019Final
Citation 1, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,400$1,190Jun 14, 2019Final
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,400$1,190Jun 14, 2019Final
Citation 1, item 5
29 CFR 1910.242(b) · Hand and power tools
Serious$600$510Jun 14, 2019Final
Citation 1, item 6
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$1,400$1,190Jun 14, 2019Final

Inspection 315847632 OPENED JUL 12, 2011Closed

Planned · Complete · Safety · 30 employees at the site · Closed Oct 13, 2011

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,200$1,200Sep 16, 2011Closed
Citation 1, item 1b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Sep 16, 2011Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,400$1,400Sep 16, 2011Closed
Citation 2, item 1
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Other-than-serious$0$0Sep 16, 2011Closed
Citation 2, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$100$100Sep 16, 2011Closed
Citation 2, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Sep 16, 2011Closed

Inspection 315720532 OPENED JUN 8, 2011Closed

Planned · Complete · Health · 32 employees at the site · Closed Jul 30, 2012

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,200$1,200Oct 13, 2011Closed
Citation 1, item 1b
29 CFR 1910.94(a)(6) · Ventilation
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1c
29 CFR 1910.134(c)(1)(vi) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1d
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1e
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1f
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1g
29 CFR 1910.134(i)(5)(iii) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1h
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1i
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1j
29 CFR 1000702 B 1
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1k
29 CFR 1000702 D
Serious$0$0Oct 13, 2011Closed
Citation 1, item 2a Serious$1,200$1,200Oct 13, 2011Closed
Citation 1, item 2b Serious$0$0Oct 13, 2011Closed
Citation 1, item 2c Serious$0$0Oct 13, 2011Closed
Citation 1, item 2d Serious$0$0Oct 13, 2011Closed
Citation 1, item 2e Serious$0$0Oct 13, 2011Closed
Citation 1, item 2f Serious$0$0Oct 13, 2011Closed
Citation 2, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$0$0Oct 13, 2011Closed
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Oct 13, 2011Closed
Citation 2, item 3
29 CFR 9000602
Other-than-serious$0$0Oct 13, 2011Closed

Inspection 311144992 OPENED JUN 14, 2007Closed

Planned · Complete · Safety · 50 employees at the site · Closed Sep 12, 2007

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$700$700Aug 7, 2007Closed
Citation 1, item 1b
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$0$0Aug 7, 2007Closed
Citation 1, item 1c
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Aug 7, 2007Closed

Inspection 306129552 OPENED FEB 26, 2003Closed

Accident · Partial · Safety · 58 employees at the site · Closed Jun 3, 2003

820 Mayberry Springs Rd, Columbia, TN 38401 · Metal Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 25, 2003 (fatal): Employee killed in fall from elevation

On February 25, 2003, Employee #1 was standing on a horizontal bridge beam of an overhead crane to access a light. He fell from the beam, approximately 25 feet and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,000$2,000Mar 28, 2003Closed
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,000$4,000Mar 28, 2003Closed
Citation 1, item 2b
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$0$0Mar 28, 2003Closed
Citation 1, item 2c
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Mar 28, 2003Closed

Inspection 305047623 OPENED FEB 1, 2002Closed

Planned · Complete · Health · 28 employees at the site · Closed Apr 9, 2003

820 Mayberry Springs Rd, Columbia, TN 38401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$350$350Apr 3, 2002Final
Citation 1, item 1b
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 1c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 1d
29 CFR 1910.134(i)(1)(ii) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 1e
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 1f
29 CFR 1910.134(i)(7) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 1g
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Apr 3, 2002Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$400$400Apr 3, 2002Final
Citation 1, item 2b
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$0$0Apr 3, 2002Final
Citation 1, item 2c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Apr 3, 2002Final
Citation 1, item 3
29 CFR 1910.1200(h) · Hazard communication
Serious$300$300Apr 3, 2002Final
Citation 2, item 1
29 CFR 9000609
Other-than-serious$0$0Apr 3, 2002Final

Inspection 114484322 OPENED MAR 17, 1993Closed

Planned · Complete · Safety · 35 employees at the site · Closed May 26, 1993

820 Mayberry Springs Rd, Columbia, TN 38401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(q)(1) · Exit routes
Serious$150$110Apr 13, 1993Closed
Citation 1, item 2
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$150$112Apr 13, 1993Closed
Citation 1, item 3
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$200$150Apr 13, 1993Closed
Citation 1, item 4
29 CFR 1910.213(i)(1) · Woodworking machinery
Serious$200$150Apr 13, 1993Closed
Citation 1, item 5
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$350$262Apr 13, 1993Closed
Citation 1, item 6
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$100$75Apr 13, 1993Closed
Citation 1, item 7a
29 CFR 1910.305(a)(2)(i) · Electrical wiring methods
Serious$150$112Apr 13, 1993Closed
Citation 1, item 7b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Apr 13, 1993Closed
Citation 1, item 8
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$150$114Apr 13, 1993Closed
Citation 2, item 1
29 CFR 3000301
Other-than-serious$0$0Apr 13, 1993Closed
Citation 2, item 2
29 CFR 1910.217(g) · Mechanical power presses
Other-than-serious$0$0Apr 13, 1993Closed
Citation 2, item 3
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Other-than-serious$0$0Apr 13, 1993Closed
1 older inspection

Inspection 114492382 OPENED FEB 16, 1993Closed

Complaint · Complete · Safety · 59 employees at the site · Closed Jan 27, 1994

820 Mayberry Springs Rd, Columbia, TN 38401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 3
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 5
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 6
29 CFR 1910.178(n)(4) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 7
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 8
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 9
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 10
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Other-than-serious$0$0Mar 3, 1993Closed
Citation 1, item 11
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 3, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

29 CFR 5030.1050

Other metal window and door manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.