Inspection 347028821 OPENED OCT 12, 2023Closed
5895 South Bellflower Drive, Littleton, CO 80120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Colorado Springs, Colorado · Roofing Contractors · NAICS 238160
Since 2014, OSHA inspectors have visited Infinity Roofing & Siding, Inc. in Colorado 9 times.
The most recent inspection opened on Oct 12, 2023, in Littleton.
In all, OSHA issued 6 citation items: 6 other-than-serious.
The proposed penalties came to $37,823; today they stand at $32,560, 14% less.
The rule cited most here is 1926.20 (construction safety programs), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Infinity Roofing & Siding, Inc. averages $8,140 across 4 cited inspections.
Colorado · latest 90 days of OSHA records
142employers cited
25 of them in the same industry
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Infinity Roofing & Siding, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company5895 South Bellflower Drive, Littleton, CO 80120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2078 S. Pontiac Way, Denver, CO 80224 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Other-than-serious | $3,856 | $3,856 | Jul 22, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(11) · Fall protection in construction |
Other-than-serious | $5,398 | $5,398 | Jul 22, 2020 | Final |
| Citation 2, item 1 29 CFR 1904.40(a) · Giving injury records to OSHA |
Other-than-serious | $771 | $771 | Jul 22, 2020 | Final |
685 Maroonglen Court, Colorado Springs, CO 80906 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5990 S. Helena St., Centennial, CO 80016 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
995 Royal Crown Lane, Colorado Springs, CO 80906 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
125 Beckwith Drive, Colorado Springs, CO 80906 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $18,293 | $16,000 | Jan 3, 2019 | Final |
19201 E Powers Pl, Aurora, CO 80015 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $4,435 | $4,000 | Sep 28, 2018 | Final |
1793 Brookside Dr, Littleton, CO 80126 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $5,070 | $2,535 | Jan 18, 2017 | Final |
9688 Bellmore Place, Highlands Ranch, CO 80126 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.40(a)
(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.
29 CFR 1926.102(a)(1)
(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.