OSHA SearchOSHA records by employer

Innocast Corporation: OSHA inspections and violations

Howard Lake, Minnesota · Glass Product Manufacturing Made of Purchased Glass · NAICS 327215

7inspections
36citation items
$6,415current penalties
Jul 5, 2018last inspection

Since 1990, OSHA inspectors have visited Innocast Corporation in Minnesota 7 times.

The most recent inspection opened on Jul 5, 2018 as a planned inspection, in Howard Lake.

In all, OSHA issued 36 citation items: 24 serious and 12 other-than-serious.

The proposed penalties came to $25,055; today they stand at $6,415, 74% less.

The rule cited most here is 1910.1025 (lead in general industry), 12 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Innocast Corporation averages $315 across 1 cited inspection.

Innocast Corporation: OSHA citation items per year, 1990 to 2018
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Innocast Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343279386 OPENED JUL 5, 2018Closed

Planned · Complete · Health · 7 employees at the site · Closed Aug 10, 2018

1315 6th St, Howard Lake, MN 55349 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$225$158Jul 17, 2018Final
Citation 1, item 2
29 CFR 1910.1200(f)(6)(i) · Hazard communication
Serious$225$158Jul 17, 2018Final

Inspection 311022917 OPENED MAY 10, 2007Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jun 13, 2007

1315 6th St, Howard Lake, MN 55349 · Other Pressed and Blown Glass and Glassware Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$450$315May 24, 2007Closed

Inspection 305289209 OPENED JUN 12, 2002Closed

Planned · Complete · Health · 15 employees at the site · Closed Jan 31, 2003

1315 6th St, Howard Lake, MN 55349 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1025(d)(6)(ii) · Lead in general industry
Serious$8,400$800Sep 27, 2002Final
Citation 1, item 1b
29 CFR 1910.1025(d)(6)(iii) · Lead in general industry
Serious$0$0Sep 27, 2002Final
Citation 1, item 2
29 CFR 1910.1025(l)(1)(v) · Lead in general industry
Serious$8,400$800Sep 27, 2002Final
Citation 2, item 1 Serious$900$600Sep 27, 2002Final
Citation 2, item 3a
29 CFR 1910.1025(c)(1) · Lead in general industry
Serious$1,200$800Sep 27, 2002Final
Citation 2, item 3b
29 CFR 1910.1025(e)(1) · Lead in general industry
Serious$0$0Sep 27, 2002Closed
Citation 2, item 3c
29 CFR 1910.1025(e)(3)(i) · Lead in general industry
Serious$0$0Sep 27, 2002Closed
Citation 2, item 4
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$1,200$400Sep 27, 2002Final
Citation 2, item 5a
29 CFR 1910.1025(i)(2)(i) · Lead in general industry
Serious$750$500Sep 27, 2002Final
Citation 2, item 5b
29 CFR 1910.1025(i)(3)(ii) · Lead in general industry
Serious$0$0Sep 27, 2002Closed
Citation 2, item 7
29 CFR 1910.1025(j)(2)(i) · Lead in general industry
Serious$600$400Sep 27, 2002Final
Citation 2, item 9
29 CFR 1910.1025(m)(2)(i) · Lead in general industry
Serious$900$200Sep 27, 2002Final
Citation 2, item 10 Serious$600$300Sep 27, 2002Final
Citation 3, item 1
29 CFR 1910.1025(g)(2)(vii) · Lead in general industry
Other-than-serious$150$150Sep 27, 2002Final

Inspection 120450895 OPENED JAN 4, 1996Closed

Planned · Complete · Safety · 22 employees at the site · Closed Mar 29, 1996

1315 6th St, Howard Lake, MN 55349 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$100$70Mar 7, 1996Closed
Citation 1, item 2
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$100$70Mar 7, 1996Closed
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Serious$100$70Mar 7, 1996Closed
Citation 1, item 4
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$100$70Mar 7, 1996Closed
Citation 2, item 1 Other-than-serious$0$0Mar 7, 1996Closed

Inspection 120394390 OPENED NOV 15, 1993Closed

Planned · Complete · Health · 22 employees at the site · Closed Feb 25, 1994

1315 6th St, Howard Lake, MN 55349 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$0$0Jan 6, 1994Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$175$75Jan 6, 1994Closed
Citation 2, item 2
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Jan 6, 1994Closed
Citation 2, item 3 Other-than-serious$0$0Jan 6, 1994Closed

Inspection 111610374 OPENED MAY 30, 1990Closed

Referral · Partial · Health · 20 employees at the site · Closed May 19, 1994

1315 6th St, Howard Lake, MN 55349 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$480$480Oct 4, 1990Closed
Citation 1, item 1b
29 CFR 1910.1000(c) · Air contaminants
Serious$0$0Oct 4, 1990Closed
Citation 1, item 1c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Oct 4, 1990Closed

Inspection 111604864 OPENED MAR 16, 1990Closed

Planned · Complete · Safety · 18 employees at the site · Closed May 19, 1994

1315 6th St, Howard Lake, MN 55349 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 2 Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 3 Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 4
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 5
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 6
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Mar 29, 1990Closed
Citation 1, item 7
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Mar 29, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(c)(1)

(c) Permissible exposure limit (PEL). (1) The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 µg/m 3) averaged over an 8-hour period.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

29 CFR 5206.700

29 CFR 5210.420

29 CFR 5210.630

Other glass product manufacturing made of purchased glass employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.