OSHA SearchOSHA records by employer

Innovative Industries, Inc.: OSHA inspections and violations

Antigo, Wisconsin · Other Motor Vehicle Parts Manufacturing · NAICS 336399

3inspections
22citation items
$6,118current penalties
Mar 27, 2015last inspection

OSHA has inspected Innovative Industries, Inc. 3 times in Wisconsin since 2003.

The latest one began on Mar 27, 2015 as a planned inspection, in Antigo.

Those inspections ended with 22 citation items: 18 serious and 4 other-than-serious.

Penalties were first proposed at $9,625 and now stand at $6,118, 36% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Innovative Industries, Inc. averages $2,082 (1 cited inspection).

Innovative Industries, Inc. also files yearly injury logs with OSHA, summarized below.

Innovative Industries, Inc.: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Innovative Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340494764 OPENED MAR 27, 2015Closed

Planned · Partial · Safety · 44 employees at the site · Closed Jul 2, 2015

1525 Deleglise St., Antigo, WI 54409 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,975$2,082Jun 12, 2015Final
Citation 1, item 1b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Jun 12, 2015Final

Inspection 312559115 OPENED NOV 23, 2010Closed

Planned · Partial · Safety · 32 employees at the site · Closed Aug 30, 2012

1525 Deleglise Street, Antigo, WI 54409 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$2,300$1,610Dec 8, 2010Closed
Citation 1, item 1b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 8, 2010Closed
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Dec 8, 2010Closed

Inspection 304017650 OPENED JUN 5, 2003Closed

Complaint · Partial · Health · 17 employees at the site · Closed Jul 16, 2003

1525 Deleglise Street, Antigo, WI 54409 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$450$250Jun 24, 2003Closed
Citation 1, item 2a
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$1,050$575Jun 24, 2003Closed
Citation 1, item 2b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jun 24, 2003Closed
Citation 1, item 2c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jun 24, 2003Closed
Citation 1, item 2d
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jun 24, 2003Closed
Citation 1, item 3a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$450$250Jun 24, 2003Closed
Citation 1, item 3b
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$0$0Jun 24, 2003Closed
Citation 1, item 4
29 CFR 1910.213(r)(4) · Woodworking machinery
Serious$750$425Jun 24, 2003Closed
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$750$425Jun 24, 2003Closed
Citation 1, item 5b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jun 24, 2003Closed
Citation 1, item 6
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$450$250Jun 24, 2003Closed
Citation 1, item 7a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$450$250Jun 24, 2003Closed
Citation 1, item 7b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jun 24, 2003Closed
Citation 1, item 7c
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jun 24, 2003Closed
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 24, 2003Closed
Citation 2, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Jun 24, 2003Closed
Citation 2, item 3
29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods
Other-than-serious$0$0Jun 24, 2003Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Antigo site logged 4 recordable injuries or illnesses among about 43 workers: 9.0 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 6 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Innovative Industries, Inc Antigo
Antigo · 2025
43 429.02.7

Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.38 · Emergency action plans

Other other motor vehicle parts manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.