OSHA SearchOSHA records by employer

International Baler Corporation: OSHA inspections and violations

Jacksonville, Florida · All Other Miscellaneous General Purpose Machinery Manufacturing · NAICS 333999

12inspections
63citation items
$17,630current penalties
Aug 19, 2025last inspection

Since 1979, OSHA inspectors have visited International Baler Corporation in Florida 12 times.

The most recent inspection opened on Aug 19, 2025 after a complaint, in Jacksonville.

In all, OSHA issued 63 citation items: 15 serious and 48 other-than-serious.

The proposed penalties came to $22,225; today they stand at $17,630, 21% less.

The rule cited most here is 1910.134 (respiratory protection), 12 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. International Baler Corporation averages $9,500 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

International Baler Corporation also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

International Baler Corporation: OSHA citation items per year, 1979 to 2025
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

311employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch International Baler Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348446790 OPENED AUG 19, 2025Closed

Complaint · Partial · Health · 30 employees at the site · Closed Feb 4, 2026

5400 Rio Grande Avenue, Jacksonville, FL 32254 · Conveyor and Conveying Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348130279 OPENED MAR 26, 2025Closed

Referral · Complete · Safety · 50 employees at the site · Closed Sep 5, 2025

5400 Rio Grande Avenue, Jacksonville, FL 32254 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$11,585$9,500Jul 2, 2025Final

Inspection 311823710 OPENED SEP 11, 2009Closed

Follow-up · Partial · Safety · 63 employees at the site · Closed Sep 28, 2009

5400 Rio Grande Avenue, Jacksonville, FL 32254 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311817563 OPENED SEP 16, 2008Closed

Accident · Complete · Safety · 63 employees at the site · Closed Apr 2, 2009

5400 Rio Grande Avenue, Jacksonville, FL 32254 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Sep 17, 2008 (fatal): Employee is electrocuted by equipment, later dies

On September 17, 2008, Employee #1 was under a baler or waste compactor that was being manufactured. He was about to use an arc welder to weld an actuator to th e press head of the LD60SD waste compactor. The waste compactor was connected to an ungrounded "transfer genny," which supplied pressurized hydraulic fluid to t he compactor via steel braided hoses. He received an electrical shock while unde r the compactor most likely from the "transfer genny," which did not have a cont inuous ground. Employee #1 was transported to a hospital, where he was induced i nto a coma until September 17, 2008, when physicians determined that he was brai n dead, and removed him from the life support system. The cause of death was fro m anoxic encephalopathy due to electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,500$1,875Mar 3, 2009Closed
Citation 1, item 2
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$875$655Mar 3, 2009Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$875$655Mar 3, 2009Closed
Citation 1, item 3b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 3, 2009Closed
Citation 1, item 4
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$4,900$3,675Mar 3, 2009Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 3
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 4
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 5
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 6
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Mar 3, 2009Closed
Citation 2, item 7
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 3, 2009Closed

Inspection 301021556 OPENED NOV 18, 1997Closed

Follow-up · Partial · Safety · 66 employees at the site · Closed Nov 18, 1997

5400 Rio Grande Avenue, Jacksonville, FL 32254 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110138245 OPENED JUL 1, 1997Closed

Referral · Partial · Health · 60 employees at the site · Closed Sep 9, 1997

5400 Rio Grande Avenue, Jacksonville, FL 32254 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 21, 1997Closed
Citation 1, item 2
29 CFR 1910.1020(g)(1)(i) · Access to employee exposure and medical records
Other-than-serious$0$0Aug 21, 1997Closed
Citation 1, item 3
29 CFR 1910.1020(g)(2) · Access to employee exposure and medical records
Other-than-serious$0$0Aug 21, 1997Closed

Inspection 301019089 OPENED JUN 30, 1997Closed

Planned · Complete · Safety · 66 employees at the site · Closed Nov 21, 1997

5400 Rio Grande Avenue, Jacksonville, FL 32254 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$525$525Oct 14, 1997Closed
Citation 1, item 1b
29 CFR 1910.107(e)(3) · Spray painting and finishing
Serious$0$0Oct 14, 1997Closed
Citation 1, item 1c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Oct 14, 1997Closed
Citation 1, item 1d
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Oct 14, 1997Closed
Citation 1, item 2a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$525$525Oct 14, 1997Closed
Citation 1, item 2b
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$0$0Oct 14, 1997Closed
Citation 2, item 1
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 2
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 3
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 4
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 5
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 6
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 14, 1997Closed
Citation 2, item 7
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Oct 14, 1997Closed

Inspection 597344 OPENED MAR 12, 1985Closed

Follow-up · Partial · Safety · 44 employees at the site · Closed Mar 12, 1985

5400 Rio Grande Avenue, Jacksonville, FL 32205 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

4 older inspections

Inspection 1979756 OPENED DEC 19, 1984Closed

Referral · Complete · Safety · 44 employees at the site · Closed Mar 1, 1985

5400 Rio Grande Ave, Jacksonville, FL 32205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$160$80Jan 11, 1985Closed
Citation 1, item 2
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$160$80Jan 11, 1985Closed
Citation 1, item 3a
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$120$60Jan 11, 1985Closed
Citation 1, item 3b
29 CFR 1910.243(c)(4) · Guarding of portable powered tools
Serious$0$0Jan 11, 1985Closed
Citation 2, item 1
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 2
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 3
29 CFR 1910.179(l)(1) · Overhead and gantry cranes
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 4
29 CFR 1910.179(l)(3)(ii) · Overhead and gantry cranes
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 5
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 6 Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 7
29 CFR 1910.242(a) · Hand and power tools
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 8
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 9
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 10
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 11
29 CFR 1910.252(b)(4)(ixc) · Welding fire safety
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 12
29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 13
29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 14
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jan 14, 1985Closed
Citation 2, item 15
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jan 14, 1985Closed

Inspection 1981554 OPENED DEC 5, 1984Closed

Planned · Complete · Health · 44 employees at the site · Closed Mar 1, 1985

5400 Rio Grande Ave, Jacksonville, FL 32205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jan 9, 1985Closed
Citation 1, item 2
29 CFR 1910.94(a)(7) · Ventilation
Other-than-serious$0$0Jan 9, 1985Closed
Citation 1, item 3
29 CFR 1910.134(b)(5) · Respiratory protection
Other-than-serious$0$0Jan 9, 1985Closed
Citation 1, item 4
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0Jan 9, 1985Closed

Inspection 13649983 OPENED JUL 30, 1982Closed

Planned · Complete · Safety · 37 employees at the site · Closed Aug 23, 1982

5400 R10 Grande, Jacksonville, FL 32209 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Aug 11, 1982Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0Aug 11, 1982Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 11, 1982Closed

Inspection 13693585 OPENED OCT 22, 1979Closed

Planned · Complete · Safety · 35 employees at the site · Closed Feb 7, 1980

5400 Rio Grande Ave, Jacksonville, FL 32205 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 2
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 3
29 CFR 1910.157(d)(2)(i) · Portable fire extinguishers
Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 4
29 CFR 1910.157(d)(3)(i) · Portable fire extinguishers
Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 5 Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 6 Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 7
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Oct 24, 1979Closed
Citation 1, item 8
29 CFR 1910.244(b) · Other portable tools and equipment
Other-than-serious$0$0Oct 24, 1979Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Jacksonville site logged 2 recordable injuries or illnesses among about 58 workers: 3.3 per 100 full-time workers, against a median of 1.9 for its industry. Those cases cost 180 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
International Baler
Jacksonville · 2025
58 213.31.9
International Baler Corporation
Jacksonville · 2020
48 111.91.9

Included with any plan: 6 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Mar 22, 2025, Jacksonville: Hospitalization, amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)

An employee was working on a press head and cylinder when his fingertips were pinched between a pin and cylinder. The employee sustained the amputation of his fingertips.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1910.1020 · Access to employee exposure and medical records

29 CFR 1910.1020(g)(1)(i)

(i) The existence, location, and availability of any records covered by this section;

29 CFR 1910.1020(g)(2)

(2) Each employer shall keep a copy of this section and its appendices, and make copies readily available, upon request, to employees. The employer shall also distribute to current employees any informational materials concerning this section which are made available to the employer by the Assistant Secretary of Labor for Occupational Safety and Health.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

Other all other miscellaneous general purpose machinery manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.