OSHA SearchOSHA records by employer

J a Piper Roofing Company: OSHA inspections and violations

Greenville, South Carolina · Roofing Contractors · NAICS 238160

25inspections
60citation items
$16,688current penalties
Jun 23, 2022last inspection

OSHA has inspected J a Piper Roofing Company 25 times in South Carolina since 1987.

The latest one began on Jun 23, 2022 on a referral, in Powdersville.

Those inspections ended with 60 citation items: 31 serious and 29 other-than-serious.

Penalties were first proposed at $22,475 and now stand at $16,688, 26% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 8 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J a Piper Roofing Company averages $6,480 (1 cited inspection).

J a Piper Roofing Company also files yearly injury logs with OSHA, summarized below.

J a Piper Roofing Company: OSHA citation items per year, 1987 to 2022
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch J a Piper Roofing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346044027 OPENED JUN 23, 2022Closed

Referral · Partial · Safety · 3 employees at the site · Closed Mar 12, 2024

2001 Easley Bridge Highway, Powdersville, SC 29673 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,200$3,480Nov 3, 2022Final
Citation 1, item 2
29 CFR 1926.502(h)(4) · Fall protection systems
Serious$1,125$0Nov 3, 2022Final
Citation 1, item 4
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$3,000$3,000Nov 3, 2022Final

Inspection 316196575 OPENED NOV 8, 2011Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 7, 2012

1300 Brushy Creek Road, Taylors, SC 29687 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$875$438Dec 13, 2011Closed

Inspection 315692525 OPENED SEP 12, 2011Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 30, 2011

308 Boulevard, Anderson, SC 29624 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Nov 7, 2011Closed

Inspection 315690891 OPENED AUG 15, 2011Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jan 18, 2012

5321 Hwy 76, Pendleton, SC 29670 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$300$150Sep 7, 2011Closed
Citation 2, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Sep 7, 2011Closed

Inspection 314695586 OPENED OCT 6, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed Feb 11, 2011

441 Congaree Road, Greenville, SC 29607 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$900$450Nov 2, 2010Closed
Citation 1, item 2
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$900$450Nov 2, 2010Closed

Inspection 312168511 OPENED JUL 30, 2008Closed

Planned · Complete · Safety · 3 employees at the site · Closed Oct 22, 2008

236 Rhett St, Greenville, SC 29601 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$450$180Aug 15, 2008Closed

Inspection 311507065 OPENED NOV 7, 2007Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Dec 27, 2007

16 Park Woodruff Rd, Greenville, SC 29607 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310972153 OPENED AUG 8, 2007Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 6, 2007

1314 S Pleasantburg Dr, Greenville, SC 29605 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$600$240Aug 28, 2007Closed
17 older inspections

Inspection 310966072 OPENED APR 4, 2007Closed

Planned · Partial · Safety · 6 employees at the site · Closed May 24, 2007

10239 Clemson Blvd, Seneca, SC 29678 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$500$500Apr 16, 2007Closed

Inspection 309803641 OPENED AUG 1, 2006Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 1, 2007

2227 Augusta Rd, Greenville, SC 29604 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$750$300Sep 5, 2006Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,125$450Sep 5, 2006Final

Inspection 309795789 OPENED MAR 15, 2006Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 26, 2006

129 N. Main St., Anderson, SC 29621 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$200$200Mar 31, 2006Closed

Inspection 303568273 OPENED DEC 5, 2001Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 12, 2002

1769 J A Cochran Bypass, Chester, SC 29706 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$400$400Jan 8, 2002Closed
Citation 2, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$400$400Jan 8, 2002Closed

Inspection 303556278 OPENED SEP 20, 2001Closed

Unprogrammed other · Partial · Health · 9 employees at the site · Closed Feb 8, 2002

Carlisle/chester Highway, Carlisle, SC 29031 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,250$2,250Dec 4, 2001Closed

Inspection 303551840 OPENED APR 25, 2001Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Jun 26, 2001

608 Johnson Rd., Central, SC 29630 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302445937 OPENED SEP 29, 1999Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 8, 2000

850 Sunny Acres Road, Pacolet, SC 29372 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$300$150Oct 26, 1999Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(viii) · Scaffolds, general requirements
Serious$400$200Oct 26, 1999Final
Citation 1, item 3a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$700$350Oct 26, 1999Final
Citation 1, item 3b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Oct 26, 1999Final
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$0Oct 26, 1999Final
Citation 2, item 2
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$0$0Oct 26, 1999Final
Citation 2, item 3a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$0$0Oct 26, 1999Final
Citation 2, item 3b
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Oct 26, 1999Final
Citation 2, item 3c
29 CFR 1926.454(b) · Scaffold training
Other-than-serious$0$0Oct 26, 1999Final

Inspection 301765111 OPENED MAY 13, 1998Closed

Follow-up · Partial · Safety · 60 employees at the site · Closed Jan 19, 1999

209 Commerce Road, Greenville, SC 29604 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301753273 OPENED MAR 24, 1998Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 27, 1998

5750 Augusta Road, Greenville, SC 29673 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301753455 OPENED AUG 13, 1997Closed

Planned · Partial · Health · 8 employees at the site · Closed Jan 19, 1999

209 Commerce Road, Greenville, SC 29604 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1101(k)(9)(i) · Asbestos in construction
Serious$500$500Sep 17, 1997Closed

Inspection 126493758 OPENED NOV 21, 1996Closed

Planned · Complete · Health · 6 employees at the site · Closed Feb 26, 1997

600 Academy Street, Clinton, SC 29325 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124655507 OPENED DEC 20, 1993Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jan 21, 1994

735 Haywood Rd., Greenville, SC 29607 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Jan 10, 1994Closed

Inspection 115688269 OPENED JUN 8, 1992Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 11, 1992

Howell Rd. & E. North St., Greenville, SC 29609 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$900$900Jun 26, 1992Closed

Inspection 107832321 OPENED AUG 10, 1989Closed

Follow-up · Partial · Safety · 50 employees at the site · Closed Feb 26, 1990

209 Commerce Road, Greenville, SC 29604 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105457519 OPENED JUN 8, 1988Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 17, 1988

I-385 South, Simpsonville, SC 29681 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105472278 OPENED MAY 25, 1988Closed

Planned · Complete · Safety · 50 employees at the site · Closed Feb 26, 1990

209 Commerce Road, Greenville, SC 29604 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$350$350Jun 22, 1988Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$350$350Jun 22, 1988Final
Citation 1, item 3a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$300$300Jun 22, 1988Final
Citation 1, item 3b
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Jun 22, 1988Final
Citation 1, item 4a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$300$300Jun 22, 1988Final
Citation 1, item 4b
29 CFR 1910.217(b)(4)(ii) · Mechanical power presses
Serious$0$0Jun 22, 1988Final
Citation 1, item 5a
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Serious$300$300Jun 22, 1988Final
Citation 1, item 5b
29 CFR 1910.217(d)(9)(i) · Mechanical power presses
Serious$0$0Jun 22, 1988Final
Citation 1, item 5c
29 CFR 1910.217(d)(6)(i) · Mechanical power presses
Serious$0$0Jun 22, 1988Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 2
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 3
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 4
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 6
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$50$50Jun 22, 1988Final
Citation 2, item 8
29 CFR 1910.213(p)(4) · Woodworking machinery
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 9
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 10
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 11
29 CFR 1910.252(b)(4)(ixc) · Welding fire safety
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 12
29 CFR 1910.252(c)(2)(vi) · Welding fire safety
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 13
29 CFR 1910.252(e)(2)(ic) · Welding fire safety
Other-than-serious$50$50Jun 22, 1988Final
Citation 2, item 14
29 CFR 1910.303(a) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 15
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 16
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 17
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 18
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 19
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 20a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 22, 1988Final
Citation 2, item 20b
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 22, 1988Final

Inspection 105423735 OPENED AUG 31, 1987Closed

Planned · Complete · Safety · 7 employees at the site · Closed Oct 6, 1987

Hidden Lake Circle, Duncan, SC 29334 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Greenville site logged 3 recordable injuries or illnesses among about 55 workers: 5.7 per 100 full-time workers, against a median of 2.8 for its industry. Those cases cost 133 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
JA Piper Roofing Co
Greenville · 2023
55 315.72.8

Included with any plan: 5 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(b)(6)(vi)

(vi) Readily ignitible material such as weeds and long dry grass shall be removed within 10 feet of any container.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.150 · Fire protection

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction