Inspection 343218947 OPENED JUN 11, 2018Closed
2805 East Centerville Road, Garland, TX 75040 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
J & a Manufacturing, Inc. has 6 OSHA inspections on record in Texas, the first in 1988.
OSHA's last visit started on Jun 11, 2018 to follow up on an earlier case, in Garland.
Across those inspections OSHA issued 16 citation items: 11 serious and 5 other-than-serious.
OSHA proposed $40,695 in penalties. After settlements and reviews the total is $16,217, down 60%.
Most often, OSHA cited 1910.134, respiratory protection (7 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. J & a Manufacturing, Inc. averages $7,871 over 2 cited inspections in that time.
J & a Manufacturing, Inc. also files yearly injury logs with OSHA, summarized below.
Texas · latest 90 days of OSHA records
399employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch J & a Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company2805 East Centerville Road, Garland, TX 75040 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2805 East Centerville Road, Garland, TX 75040 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2805 East Centerville Road, Garland, TX 75040 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $8,873 | $3,550 | Oct 19, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.134(e)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Oct 19, 2017 | Final |
| Citation 1, item 1c 29 CFR 1910.134(f)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Oct 19, 2017 | Final |
2805 East Centerville Road, Garland, TX 75040 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $8,873 | $3,550 | Oct 19, 2017 | Final |
| Citation 1, item 3 29 CFR 1910.178(l)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $8,873 | $3,550 | Oct 19, 2017 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $6,338 | $2,550 | Oct 19, 2017 | Final |
| Citation 1, item 6 29 CFR 1910.243(b)(2) · Guarding of portable powered tools |
Serious | $6,338 | $2,542 | Oct 19, 2017 | Final |
2805 E. Centerville Road, Garland, TX 75040 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $225 | $0 | Aug 28, 1991 | Final |
| Citation 1, item 2 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Serious | $225 | $225 | Aug 28, 1991 | Final |
| Citation 1, item 3 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $225 | $0 | Aug 28, 1991 | Final |
| Citation 1, item 4a 29 CFR 1910.134(b)(1) · Respiratory protection |
Serious | $500 | $250 | Aug 28, 1991 | Final |
| Citation 1, item 4b 29 CFR 1910.134(b)(3) · Respiratory protection |
Serious | $0 | $0 | Aug 28, 1991 | Final |
| Citation 1, item 4c 29 CFR 1910.134(b)(5) · Respiratory protection |
Serious | $0 | $0 | Aug 28, 1991 | Final |
| Citation 1, item 4d 29 CFR 1910.134(b)(6) · Respiratory protection |
Serious | $0 | $0 | Aug 28, 1991 | Final |
| Citation 1, item 5 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $225 | $0 | Aug 28, 1991 | Final |
319 Country Club, Garland, TX 75040 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 26, 1988 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Garland site logged 2 recordable injuries or illnesses among about 37 workers: 6.1 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 1 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| J & A Manufacturing, Inc. Garland · 2025 | 37 | 2 | 1 | 6.1 | 3.6 |
| J & A Manufacturing Inc Garland · 2024 | 39 | 0 | 0 | 0.0 | 3.6 |
Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.