OSHA SearchOSHA records by employer

J & K Privette Masonry, Inc.: OSHA inspections and violations

Statesville, North Carolina · Masonry Contractors · NAICS 238140

3inspections
14citation items
$6,240current penalties
Oct 16, 2015last inspection

Since 2003, OSHA inspectors have visited J & K Privette Masonry, Inc. in North Carolina 3 times.

The most recent inspection opened on Oct 16, 2015 as a planned inspection, in Salisbury.

In all, OSHA issued 14 citation items: 11 serious and 3 other-than-serious.

The proposed penalties came to $12,200; today they stand at $6,240, 49% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J & K Privette Masonry, Inc. averages $5,040 across 1 cited inspection.

J & K Privette Masonry, Inc.: OSHA citation items per year, 2003 to 2015
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch J & K Privette Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340994219 OPENED OCT 16, 2015Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jan 13, 2017

Bldg 42, Salisbury, NC 28144 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,800$2,520Jan 4, 2016Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$0Jan 4, 2016Final
Citation 1, item 1c
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Jan 4, 2016Final
Citation 1, item 2a
29 CFR 1926.454(a) · Scaffold training
Serious$2,800$2,520Jan 4, 2016Final
Citation 1, item 2b
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$0$0Jan 4, 2016Final
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Jan 4, 2016Final
Citation 2, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$1,200$0Jan 4, 2016Final

Inspection 308496553 OPENED NOV 19, 2004Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Feb 23, 2005

301 South Center Street, Statesville, NC 28677 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,100$700Jan 4, 2005Closed

Inspection 306550351 OPENED MAR 28, 2003Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed May 12, 2003

Cool Springs Road, Statesville, NC 28625 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$250$250Apr 4, 2003Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Apr 4, 2003Closed
Citation 1, item 1c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Apr 4, 2003Closed
Citation 1, item 2a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$250$250Apr 4, 2003Closed
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 4, 2003Closed
Citation 2, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 4, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.