OSHA SearchOSHA records by employer

J Monkey Construction Co: OSHA inspections and violations

Dover, New Hampshire · Roofing Contractors · NAICS 238160

2inspections
9citation items
$11,460current penalties
Jul 11, 2022last inspection

Since 2018, OSHA inspectors have visited J Monkey Construction Co in New Hampshire 2 times.

The most recent inspection opened on Jul 11, 2022 as a planned inspection, in Rochester.

In all, OSHA issued 9 citation items: 9 serious.

The proposed penalties came to $19,570; today they stand at $11,460, 41% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J Monkey Construction Co averages $5,730 across 2 cited inspections.

J Monkey Construction Co: OSHA citation items per year, 2018 to 2022
Citation items per year, by inspection date.

New Hampshire · latest 90 days of OSHA records

50employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Hampshire

Checking a subcontractor, a client or your own company? Watch J Monkey Construction Co and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346087489 OPENED JUL 11, 2022Closed

Planned · Partial · Safety · 8 employees at the site · Closed Sep 25, 2023

9 Wildcat Drive., Rochester, NH 03839 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$3,108$1,500Sep 27, 2022Final
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Sep 27, 2022Final
Citation 1, item 1c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 27, 2022Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,351$2,200Sep 27, 2022Final
Citation 1, item 2b
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$0$0Sep 27, 2022Final
Citation 1, item 2c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,351$0Sep 27, 2022Final

Inspection 343365110 OPENED AUG 7, 2018Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jan 25, 2021

3 Governor Sawyer Lane, Dover, NH 03820 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,880$3,880Aug 29, 2018Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,880$3,880Aug 29, 2018Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Aug 29, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in New Hampshire

Alert subscribers get notified of each newly cited employer in New Hampshire the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.