OSHA SearchOSHA records by employer

JBS, LLC: OSHA inspections and violations

Johnstown, New York · Fabricated Structural Metal Manufacturing · NAICS 332312

7inspections
17citation items
$17,826current penalties
Mar 6, 2018last inspection

JBS, LLC has 7 OSHA inspections on record in New York, the first in 2002.

OSHA's last visit started on Mar 6, 2018 to follow up on an earlier case, in Johnstown.

Across those inspections OSHA issued 17 citation items: 15 serious and 2 other-than-serious.

OSHA proposed $34,008 in penalties. After settlements and reviews the total is $17,826, down 48%.

Most often, OSHA cited 1910.178, forklifts and other powered industrial trucks (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. JBS, LLC averages $8,063 over 2 cited inspections in that time.

JBS, LLC: OSHA citation items per year, 2002 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites JBS, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342993763 OPENED MAR 6, 2018Closed

Follow-up · Partial · Safety · 12 employees at the site · Closed Mar 27, 2018

125 West Fulton St, Johnstown, NY 12095 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341816106 OPENED OCT 5, 2016Closed

Referral · Partial · Health · 14 employees at the site · Closed Mar 18, 2019

125 West Fulton St, Johnstown, NY 12095 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$3,622$2,535Mar 1, 2017Final
Citation 1, item 2
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$3,622$0Mar 1, 2017Final
Citation 1, item 3
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$3,622$2,535Mar 1, 2017Final
Citation 1, item 4
29 CFR 1910.107(c)(7) · Spray painting and finishing
Serious$3,622$0Mar 1, 2017Final
Citation 1, item 5a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,622$2,535Mar 1, 2017Final
Citation 1, item 5b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Mar 1, 2017Final
Citation 1, item 5c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Mar 1, 2017Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,622$2,535Mar 1, 2017Final
Citation 1, item 6b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 1, 2017Final
Citation 1, item 6c
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$0$0Mar 1, 2017Final

Inspection 341708808 OPENED AUG 18, 2016Closed

Referral · Partial · Safety · 12 employees at the site · Closed Dec 31, 2018

125 West Fulton St, Johnstown, NY 12095 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$4,988$2,992Oct 26, 2016Final
Citation 1, item 2
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$4,988$2,992Oct 26, 2016Final
Citation 2, item 1
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 26, 2016Final

Inspection 313756249 OPENED JAN 8, 2010Closed

Planned · No inspection · Safety · Closed Jan 8, 2010

6 Maple Avenue, Scotia, NY 12302 · Corporate, Subsidiary, and Regional Managing Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310519624 OPENED MAR 22, 2007Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 9, 2007

Lower Newtown Road, Halfmoon, NY 12188 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307533000 OPENED MAY 4, 2004Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Jun 23, 2004

Schalmont Middle/high School, 1 Sabre Drive, Schenectady, NY 12306 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.303(b)(1) · Abrasive wheels and tools
Serious$800$800May 12, 2004Closed
Citation 2, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0May 12, 2004Closed

Inspection 304468648 OPENED JUL 31, 2002Closed

Complaint · Complete · Safety · 4 employees at the site · Closed Nov 14, 2002

Route 2, Tamarack High School, Brunswick, NY 12111 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$750$450Aug 29, 2002Closed
Citation 1, item 2
29 CFR 1926.761(b) · Training
Serious$750$450Aug 29, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.303 · Abrasive wheels and tools

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.760 · Fall protection

29 CFR 1926.761 · Training

Other fabricated structural metal manufacturing employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.