OSHA has inspected Jewell Electric Inc. 4 times in Pennsylvania since 2002.

The latest one began on Feb 6, 2023 on a referral, in Dubois.

Those inspections ended with 16 citation items: 14 serious and 2 other-than-serious.

Penalties were first proposed at $34,352 and now stand at $21,890, 36% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 3 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jewell Electric Inc. averages $21,500 (1 cited inspection).

Jewell Electric Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Jewell Electric Inc.: OSHA citation items per year, 2002 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Jewell Electric Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346485204 OPENED FEB 6, 2023Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jun 12, 2026

100 Hospital Avenue, Dubois, PA 15801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$8,438$5,375May 23, 2023Final
Citation 1, item 1b
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$0$0May 23, 2023Final
Citation 1, item 2a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$8,438$5,375May 23, 2023Final
Citation 1, item 2b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0May 23, 2023Final
Citation 1, item 2c
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$0$0May 23, 2023Final
Citation 1, item 3a
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$8,438$5,375May 23, 2023Final
Citation 1, item 3b
29 CFR 1926.97(c)(2)(viii) · Electrical protective equipment
Serious$0$0May 23, 2023Final
Citation 1, item 4
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$8,438$5,375May 23, 2023Final

Inspection 346207855 OPENED SEP 8, 2022Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jan 31, 2023

100 Hospital Avenue, Dubois, PA 15801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346209398 OPENED SEP 8, 2022Closed

Planned · Complete · Health · 2 employees at the site · Closed Feb 8, 2023

100 Hospital Avenue, Dubois, PA 15801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303711188 OPENED DEC 10, 2002Closed

Unprogrammed other · Complete · Safety · 15 employees at the site · Closed Jan 6, 2003

200 Maplevale Road, Brookville, PA 15825 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$300$190Dec 20, 2002Closed
Citation 1, item 1b
29 CFR 1926.405(a)(2)(iij) · Job-site wiring
Serious$0$0Dec 20, 2002Closed
Citation 1, item 1c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Dec 20, 2002Closed
Citation 1, item 1d
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Dec 20, 2002Closed
Citation 1, item 2a
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$300$200Dec 20, 2002Closed
Citation 1, item 2b
29 CFR 1926.403(i)(2)(ii) · Electrical equipment on job sites
Serious$0$0Dec 20, 2002Closed
Citation 2, item 1
29 CFR 1926.250(a)(3) · General requirements for storage
Other-than-serious$0$0Dec 20, 2002Closed
Citation 2, item 2
29 CFR 1926.1052(a)(4) · Stairways in construction
Other-than-serious$0$0Dec 20, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Dubois site logged 1 recordable injury or illness among about 26 workers: 4.2 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Office
Dubois · 2024
26 104.21.8
Jewell Electric Inc
Dubois · 2023
27 217.51.8

Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 31, 2023, Dubois: Hospitalization · electrocutions, electric shocks · body systems

An employee was removing old wiring on an old fire pump. While relocating wires inside the old switchgear, an employee received an electrical shock. The employee was pulled from the switchgear by a co-worker due to the electrical current holding them to the switchgear. At that time, the employee also received a laceration to his left hand and forearm. The breaker was locked out/tagged out at the time.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(a)(4)

(4) Where doors or gates open directly on a stairway, a platform shall be provided, and the swing of the door shall not reduce the effective width of the platform to less than 20 inches (51 cm).

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.95 · Criteria for personal protective equipment

29 CFR 1926.97 · Electrical protective equipment

Other electrical contractors and other wiring installation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.