Jomar Corporation has 7 OSHA inspections on record in New Jersey, the first in 1982.
OSHA's last visit started on Jun 9, 2026 as a planned inspection, in Egg Harbor Township, and the case has not closed yet.
Across those inspections OSHA issued 29 citation items: 21 serious and 8 other-than-serious.
OSHA proposed $54,787 in penalties. After settlements and reviews the total is $38,637, down 29%.
Most often, OSHA cited 1910.107, spray painting and finishing (6 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Jomar Corporation averages $28,137 over 1 cited inspection in that time.
Jomar Corporation also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
New Jersey · latest 90 days of OSHA records
276employers cited
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Egg Harbor Township site logged 2 recordable injuries or illnesses among about 34 workers: 6.2 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 48 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Jomar Corp
Egg Harbor Township · 2025
34
2
1
6.2
2.1
Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(c)(9)(i)
(9) Grounding. (i) All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) or aerated solids shall be properly electrically grounded in an effective and permanent manner.
29 CFR 1910.107(e)(2)
(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.
Meto Lift IncFranklin Lakes · 24 citations · $21,786