OSHA SearchOSHA records by employer

JRK Steel Inc: OSHA inspections and violations

Duluth, Minnesota · Fabricated Structural Metal Manufacturing · NAICS 332312

2inspections
20citation items
$11,025current penalties
Jan 22, 2025last inspection

Since 2021, OSHA inspectors have visited JRK Steel Inc in Minnesota 2 times.

The most recent inspection opened on Jan 22, 2025 as a planned inspection, in Duluth.

In all, OSHA issued 20 citation items: 12 serious, 2 repeat and 6 other-than-serious.

The proposed penalties came to $20,300; today they stand at $11,025, 46% less.

The rule cited most here is 5205.1200 (), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. JRK Steel Inc averages $5,512 across 2 cited inspections.

JRK Steel Inc: OSHA citation items per year, 2021 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

371employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch JRK Steel Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348001215 OPENED JAN 22, 2025Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jul 1, 2025

5900 Main St, Duluth, MN 55807 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Repeat$1,750$875Mar 27, 2025Final
Citation 1, item 2 Repeat$1,750$875Mar 27, 2025Final
Citation 2, item 1
29 CFR 182.676
Serious$350$175Mar 27, 2025Final
Citation 2, item 2
29 CFR 1910.107(c)(2) · Spray painting and finishing
Other-than-serious$1,750$875Mar 27, 2025Final
Citation 2, item 3
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$2,100$1,050Mar 27, 2025Final
Citation 2, item 4
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$1,400$700Mar 27, 2025Final
Citation 2, item 5
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,750$875Mar 27, 2025Final
Citation 2, item 6
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,750$875Mar 27, 2025Final
Citation 2, item 7
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$1,750$875Mar 27, 2025Final
Citation 2, item 8 Serious$1,050$525Mar 27, 2025Final
Citation 2, item 9
29 CFR 1910.242(b) · Hand and power tools
Serious$1,050$525Mar 27, 2025Final
Citation 2, item 10
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$1,400$700Mar 27, 2025Final
Citation 3, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$700$350Mar 27, 2025Final

Inspection 345406805 OPENED JUL 7, 2021Closed

Planned · Complete · Safety · 16 employees at the site · Closed Sep 13, 2021

5900 Main St, Duluth, MN 55807 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Serious$250$250Jul 23, 2021Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$625$625Jul 23, 2021Final
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$500$500Jul 23, 2021Final
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 23, 2021Final
Citation 2, item 2 Other-than-serious$125$125Jul 23, 2021Final
Citation 2, item 3 Other-than-serious$125$125Jul 23, 2021Final
Citation 2, item 4 Other-than-serious$125$125Jul 23, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 5205.1200

29 CFR 5205.1210

Other fabricated structural metal manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.