Inspection 344354873 OPENED OCT 3, 2019Closed
4260 Palm Avenue, Hialeah, FL 33012 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Oct 3, 2019 (fatal): Employee is killed by contact with high voltage line
At 11:45 a.m. on October 3, 2019, Employee #1 was preparing to install a wire reinforcement panel, on top of a concrete block wall, during residential construction. Employee #1 was moving wire reinforcement, within 54 inches, of a 7.2 kV, overhead transmission power line and accidentally, contacted the power line. Employee #1 suffered severe electrical shock, was electrocuted and killed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $4,048 | $4,048 | Apr 2, 2020 | Final |
| Citation 1, item 1b 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $0 | $0 | Apr 2, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.25(a) · Housekeeping |
Serious | $3,470 | $3,470 | Apr 2, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $13,494 | $13,494 | Apr 2, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(9) · Fall protection in construction |
Serious | $4,048 | $4,048 | Apr 2, 2020 | Final |
| Citation 1, item 5 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $4,048 | $4,048 | Apr 2, 2020 | Final |