OSHA SearchOSHA records by employer

Juan Fernando Mayen: OSHA inspections and violations

Corpus Christi, Texas · Wood Window and Door Manufacturing · NAICS 321911

1inspections
15citation items
$4,800current penalties
Jun 22, 2016last inspection

OSHA inspectors have visited Juan Fernando Mayen in Texas one time.

It opened on Jun 22, 2016 as a planned inspection, in Corpus Christi.

In all, OSHA issued 15 citation items: 8 serious and 7 other-than-serious.

The proposed penalties came to $8,000; today they stand at $4,800, 40% less.

The rule cited most here is 1910.213 (woodworking machinery), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Juan Fernando Mayen averages $4,800 across 1 cited inspection.

Juan Fernando Mayen: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Juan Fernando Mayen and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341573954 OPENED JUN 22, 2016Closed

Planned · Complete · Health · 12 employees at the site · Closed Aug 12, 2016

3735 Wow Rd, Corpus Christi, TX 78413 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,800$1,680Jul 28, 2016Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,000$1,200Jul 28, 2016Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jul 28, 2016Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jul 28, 2016Final
Citation 1, item 3a
29 CFR 1910.213(b)(3) · Woodworking machinery
Serious$2,800$1,680Jul 28, 2016Final
Citation 1, item 3b
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$0$0Jul 28, 2016Final
Citation 1, item 3c
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jul 28, 2016Final
Citation 1, item 3d
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jul 28, 2016Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Jul 28, 2016Final
Citation 2, item 2
29 CFR 1910.38(b) · Emergency action plans
Other-than-serious$0$0Jul 28, 2016Final
Citation 2, item 3
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$400$240Jul 28, 2016Final
Citation 2, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Jul 28, 2016Final
Citation 2, item 5
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 28, 2016Final
Citation 2, item 6
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 28, 2016Final
Citation 2, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 28, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.38 · Emergency action plans

29 CFR 1910.95 · Noise

Other wood window and door manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.