Jun 24, 2015last inspection

Since 1973, OSHA inspectors have visited Kasper Construction, LLC in Wisconsin 3 times.

The most recent inspection opened on Jun 24, 2015 as a planned inspection, in Shorewood.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The proposed penalties came to $6,325; today they stand at $4,165, 34% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kasper Construction, LLC averages $2,640 across 1 cited inspection.

Kasper Construction, LLC: OSHA citation items per year, 1973 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Kasper Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340734417 OPENED JUN 24, 2015Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jul 1, 2016

4125 North Lake Dr., Shorewood, WI 53211 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$1,540Jul 14, 2015Final
Citation 1, item 2a
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,000$1,100Jul 14, 2015Final
Citation 1, item 2b
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$0$0Jul 14, 2015Final

Inspection 307059956 OPENED MAR 8, 2005Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 14, 2005

7029 Carmel Dr., Franklin, WI 53132 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,500$1,500Mar 18, 2005Closed

Inspection 15584741 OPENED APR 24, 1973Closed

Planned · Partial · Safety · 6 employees at the site · Closed Mar 10, 1984

Mirro Drive Plant #7, Manitowoc, WI 54220 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.450(a)(2) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0May 11, 1973Closed
Citation 1, item 2
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Other-than-serious$25$25May 11, 1973Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.450(a)(2)

(a) Scope and application. This subpart applies to all scaffolds used in workplaces covered by this part. It does not apply to crane or derrick suspended personnel platforms. The criteria for aerial lifts are set out exclusively in § 1926.453.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction