Ken Garner Manufacturing - Rho Inc. has 4 OSHA inspections on record in North Carolina, the first in 2014.
OSHA's last visit started on May 5, 2025 after a complaint, in Rural Hall.
Across those inspections OSHA issued 8 citation items: 3 serious and 5 other-than-serious.
OSHA proposed $3,775 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.134, respiratory protection (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Ken Garner Manufacturing - Rho Inc. averages $750 over 2 cited inspections in that time.
Ken Garner Manufacturing - Rho Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
North Carolina · latest 90 days of OSHA records
226employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Ken Garner Manufacturing - Rho Inc. and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Rural Hall site logged 5 recordable injuries or illnesses among about 57 workers: 14.1 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 16 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Ken Garner Manufacturing RHO
Rural Hall · 2024
57
5
1
14.1
2.7
Ken Garner Manufacturing - RHO
Rural Hall · 2021
35
0
0
0.0
3.4
Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.