OSHA SearchOSHA records by employer

Ketchie-Houston, Inc.: OSHA inspections and violations

Concord, North Carolina · Ball and Roller Bearing Manufacturing · NAICS 332991

5inspections
22citation items
$1,250current penalties
Apr 25, 2016last inspection

Since 1989, OSHA inspectors have visited Ketchie-Houston, Inc. in North Carolina 5 times.

The most recent inspection opened on Apr 25, 2016 to follow up on an earlier case, in Concord.

In all, OSHA issued 22 citation items: 3 serious and 19 other-than-serious.

The penalties, $1,250 in total, stand where OSHA first set them.

The rule cited most here is 1910.107 (spray painting and finishing), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Ketchie-Houston, Inc. averages $900 across 1 cited inspection.

Ketchie-Houston, Inc. also files yearly injury logs with OSHA, summarized below.

Ketchie-Houston, Inc.: OSHA citation items per year, 1989 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Ketchie-Houston, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341441848 OPENED APR 25, 2016Closed

Follow-up · Partial · Safety · 28 employees at the site · Closed May 17, 2016

201 Winecoff School Road, Concord, NC 28027 · Ball and Roller Bearing Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341092443 OPENED DEC 1, 2015Closed

Complaint · Partial · Safety · 28 employees at the site · Closed Feb 2, 2016

201 Winecoff School Road, Concord, NC 28027 · Ball and Roller Bearing Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$450$450Jan 6, 2016Final
Citation 1, item 1b
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Serious$0$0Jan 6, 2016Final
Citation 2, item 1
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$450$450Jan 6, 2016Final

Inspection 314200908 OPENED FEB 17, 2010Closed

Planned · Complete · Safety · 20 employees at the site · Closed Mar 1, 2010

201 Winecoff School Road, Concord, NC 28027 · Ball and Roller Bearing Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 24, 2010Closed
Citation 1, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Feb 24, 2010Closed
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 24, 2010Closed
Citation 1, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 24, 2010Closed

Inspection 310583703 OPENED NOV 7, 2006Closed

Planned · Complete · Safety · 21 employees at the site · Closed Jan 22, 2007

201 Winecoff School Road, Concord, NC 28027 · Iron and Steel Forging · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$350$350Dec 14, 2006Closed
Citation 2, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 2
29 CFR 1910.107(b)(5)(ii) · Spray painting and finishing
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 3
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 4
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 5
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 6
29 CFR 1910.138(b) · Gloves and hand protection
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 7
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Dec 14, 2006Closed
Citation 2, item 8
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 14, 2006Closed

Inspection 18513218 OPENED MAY 23, 1989Closed

Planned · Complete · Safety · 27 employees at the site · Closed Jul 27, 1989

201 Winecoff School Rd., Concord, NC 28025 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jun 23, 1989Closed
Citation 1, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Jun 23, 1989Closed
Citation 1, item 3
29 CFR 1910.107(b)(6) · Spray painting and finishing
Other-than-serious$0$0Jun 23, 1989Closed
Citation 1, item 4
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Other-than-serious$0$0Jun 23, 1989Closed
Citation 1, item 5 Other-than-serious$0$0Jun 23, 1989Closed
Citation 1, item 6 Other-than-serious$0$0Jun 23, 1989Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Concord site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Ketchie Houston Inc
Concord · 2025
20 000.02.7
Ketchie Inc.
Concord · 2023
25 105.02.7
Ketchie-Houston Inc
Concord · 2022
23 114.62.7

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(ii)

(ii) All discarded filter pads and filter rolls shall be immediately removed to a safe, well-detached location or placed in a water-filled metal container and disposed of at the close of the day's operation unless maintained completely in water.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other ball and roller bearing manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.