Inspection 347889396 OPENED NOV 20, 2024Closed
520 North Main Street, Kewaunee, WI 54216 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Kewaunee Fabrications, L.L.C. 3 times in Wisconsin since 2022.
The latest one began on Nov 20, 2024 to follow up on an earlier case, in Kewaunee.
Those inspections ended with 24 citation items: 19 serious, 1 repeat and 4 other-than-serious.
Penalties were first proposed at $320,439 and now stand at $241,539, 25% lower after settlements or reviews.
Hexavalent chromium comes up most often in these citations: 9 items under 1910.1026.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Kewaunee Fabrications, L.L.C. averages $120,770 (2 cited inspections).
It reported 1 severe injury to OSHA since 2015.
Wisconsin · latest 90 days of OSHA records
218employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wisconsin
Checking a subcontractor, a client or your own company? Watch Kewaunee Fabrications, L.L.C. and get notified the morning OSHA posts a new citation for it.
Watch this company520 North Main Street, Kewaunee, WI 54216 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
520 North Main Street, Kewaunee, WI 54216 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1026(c) · Hexavalent chromium |
Serious | $13,005 | $13,005 | Mar 28, 2025 | Final |
| Citation 1, item 1b 29 CFR 1910.1026(e)(2) · Hexavalent chromium |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 1c 29 CFR 1910.1026(f)(1)(i) · Hexavalent chromium |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 1d 29 CFR 1910.1026(i)(5) · Hexavalent chromium |
Serious | $13,005 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 3a 29 CFR 1910.1026(k)(1)(i)(a) · Hexavalent chromium |
Serious | $13,005 | $13,005 | Mar 28, 2025 | Final |
| Citation 1, item 3b 29 CFR 1910.1026(k)(2)(ii) · Hexavalent chromium |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 3c 29 CFR 1910.1026(l)(1) · Hexavalent chromium |
Serious | $13,005 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 3d 29 CFR 1910.1200(h)(2)(ii) · Hazard communication |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 3e 29 CFR 1910.1200(h)(3)(ii) · Hazard communication |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 3f 29 CFR 1910.1200(h)(3)(iii) · Hazard communication |
Serious | $0 | $0 | Mar 28, 2025 | Final |
| Citation 1, item 5a 29 CFR 1910.1026(l)(1)(iii) · Hexavalent chromium |
Serious | $13,005 | $13,005 | Mar 28, 2025 | Final |
| Citation 1, item 5b 29 CFR 1910.1026(l)(2) · Hexavalent chromium |
Serious | $13,005 | $0 | Mar 28, 2025 | Final |
| Citation 2, item 1 29 CFR 1910.134(c)(1)(v) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 28, 2025 | Final |
520 North Main Street, Kewaunee, WI 54216 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $14,502 | $14,502 | Dec 5, 2022 | Final |
| Citation 1, item 3a 29 CFR 1910.178(o)(1) · Forklifts and other powered industrial trucks |
Serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 3b 29 CFR 1910.178(o)(2) · Forklifts and other powered industrial trucks |
Serious | $0 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 4 29 CFR 1910.178(l)(3)(ii)(b) · Forklifts and other powered industrial trucks |
Serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 5 29 CFR 1910.184(i)(9) · Slings |
Other-than-serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 6 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 7 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 8 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 9 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 1, item 10 29 CFR 1910.333(c)(2) · Working near live electrical parts |
Serious | $10,360 | $7,000 | Dec 5, 2022 | Final |
| Citation 2, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Repeat | $145,027 | $125,022 | Dec 5, 2022 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jun 7, 2022, Kewaunee: Hospitalization · fractures · leg(s), unspecified
An employee was moving a 1,200-pound block of steel using a jib crane with a magnet. The magnet failed and the part fell off, breaking the employee's leg.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1026(c)
(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).
29 CFR 1910.1026(e)(2)
(2) Demarcation. The employer shall ensure that regulated areas are demarcated from the rest of the workplace in a manner that adequately establishes and alerts employees of the boundaries of the regulated area.
29 CFR 1910.1026(f)(1)(i)
(f) Methods of compliance—(1) Engineering and work practice controls. (i) Except as permitted in paragraph (f)(1)(ii) and paragraph (f)(1)(iii) of this section, the employer shall use engineering and work practice controls to reduce and maintain employee exposure to chromium (VI) to or below the PEL unless the employer can demonstrate that such controls are not feasible. Wherever feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall use them to reduce employee exposure to the lowest levels achievable, and shall supplement them by the use of respiratory protection that complies with the requirements of paragraph (g) of this section.
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.