Kinetic Systems Incorporated: OSHA inspections and violations
Boston, Massachusetts · Surgical and Medical Instrument Manufacturing · NAICS 339112
7inspections
28citation items
$8,138current penalties
Oct 17, 2019last inspection
OSHA has inspected Kinetic Systems Incorporated 7 times in Massachusetts since 1992.
The latest one began on Oct 17, 2019 on a referral, in Roslindale.
Those inspections ended with 28 citation items: 19 serious and 9 other-than-serious.
Penalties were first proposed at $26,610 and now stand at $8,138, 69% lower after settlements or reviews.
Woodworking machinery comes up most often in these citations: 4 items under 1910.213.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Kinetic Systems Incorporated averages $2,000 (1 cited inspection).
Kinetic Systems Incorporated also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Massachusetts · latest 90 days of OSHA records
249employers cited
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Kinetic Systems Incorporated and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2017, the Roslindale site logged 2 recordable injuries or illnesses among about 25 workers: 9.1 per 100 full-time workers, against a median of 0.6 for its industry. Those cases cost 90 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Kinetic Systems Inc
Roslindale · 2017
25
2
1
9.1
0.6
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
29 CFR 1910.107(b)(6)
(6) Frontal area. Each spray booth having a frontal area larger than 9 square feet shall have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening.
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.