Inspection 348926759 OPENED MAY 7, 2026Closed
90 Twin Springs Road, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Newberry, South Carolina · Other Fabricated Wire Product Manufacturing · NAICS 332618
OSHA has inspected Kiswire Inc 11 times in South Carolina since 2004.
The latest one began on May 7, 2026 after a complaint, in Newberry.
Those inspections ended with 66 citation items: 54 serious, 1 repeat and 11 other-than-serious.
Penalties were first proposed at $38,375 and now stand at $27,488, 28% lower after settlements or reviews.
Lead in general industry comes up most often in these citations: 30 items under 1910.1025.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Kiswire Inc averages $5,125 (2 cited inspections).
Kiswire Inc also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Kiswire Inc again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company90 Twin Springs Road, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
90 Twin Springs Road, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1.12(A) |
Serious | $4,500 | $4,500 | Apr 30, 2024 | Final |
| Citation 1, item 2 29 CFR 3.39(A) |
Serious | $3,750 | $3,750 | Apr 30, 2024 | Final |
257 Mawsons Way, Newberry, SC 29108 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
257 Mawsons Way And 90 Twin Springs Road, Newberry, SC 29108 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 4a 29 CFR 1910.1025(h)(1) · Lead in general industry |
Serious | $4,000 | $2,000 | Sep 2, 2015 | Closed |
| Citation 1, item 4b 29 CFR 1910.1025(i)(2)(ii) · Lead in general industry |
Serious | $4,000 | $0 | Sep 2, 2015 | Closed |
| Citation 1, item 4c 29 CFR 1910.1025(i)(3)(ii) · Lead in general industry |
Serious | $4,000 | $0 | Sep 2, 2015 | Closed |
257 Mawsons Way, Newberry, SC 29108 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1910.1025(h)(2)(ii) · Lead in general industry |
Serious | $0 | $562 | May 21, 2013 | Closed |
| Citation 1, item 3b 29 CFR 1910.1025(m)(2)(i) · Lead in general industry |
Serious | $0 | $0 | May 21, 2013 | Closed |
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 3, item 1 29 CFR 1910.1025(f)(3)(i) · Lead in general industry |
Serious | $0 | $0 | Sep 5, 2006 | Closed |
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1910.1025(i)(4)(iii) · Lead in general industry |
Serious | $0 | $850 | Dec 8, 2005 | Closed |
| Citation 1, item 3b 29 CFR 1910.1025(i)(4)(iv) · Lead in general industry |
Serious | $0 | $0 | Dec 8, 2005 | Closed |
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.1025(f)(1) · Lead in general industry |
Serious | $1,125 | $1,125 | Jun 28, 2005 | Final |
| Citation 1, item 2 29 CFR 1910.1025(j)(2)(i) · Lead in general industry |
Serious | $1,125 | $1,125 | Jun 28, 2005 | Final |
| Citation 1, item 3 29 CFR 1910.1025(j)(2)(ii) · Lead in general industry |
Serious | $1,125 | $1,125 | Jun 28, 2005 | Final |
| Citation 2, item 1 29 CFR 1910.1025(f)(2)(i) · Lead in general industry |
Serious | $2,400 | $1,200 | Jun 28, 2005 | Final |
| Citation 2, item 2 29 CFR 1910.1025(l)(1)(i) · Lead in general industry |
Repeat | $3,000 | $3,000 | Jun 28, 2005 | Final |
| Citation 3, item 1 29 CFR 1910.1025(k)(2)(i) · Lead in general industry |
Other-than-serious | $0 | $0 | Jun 28, 2005 | Final |
| Citation 3, item 2a 29 CFR 30004 A |
Other-than-serious | $450 | $450 | Jun 28, 2005 | Final |
| Citation 3, item 2b 29 CFR 30031 B |
Other-than-serious | $0 | $0 | Jun 28, 2005 | Final |
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 3, item 9a 29 CFR 1910.134(a)(1) · Respiratory protection |
Serious | $5,000 | $5,000 | May 3, 2004 | Final |
| Citation 3, item 9b 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9d 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9e 29 CFR 1910.1025(d)(7) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9f 29 CFR 1910.1025(g)(1) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9g 29 CFR 1910.1025(j)(1)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9h 29 CFR 1910.1025(c)(1) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9i 29 CFR 1910.1025(e)(1)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9j 29 CFR 1910.1025(e)(3)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9k 29 CFR 1910.1025(h)(1) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9l 29 CFR 1910.1025(h)(2)(ii) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9m 29 CFR 1910.1025(i)(2)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9n 29 CFR 1910.1025(i)(3)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9o 29 CFR 1910.1025(i)(4)(ii) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9p 29 CFR 1910.1025(i)(4)(iii) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9q 29 CFR 1910.1025(i)(4)(iv) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9r 29 CFR 1910.1025(l)(1)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9s 29 CFR 1910.1025(l)(1)(ii) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
| Citation 3, item 9t 29 CFR 1910.1025(m)(2)(i) · Lead in general industry |
Serious | $0 | $0 | May 3, 2004 | Final |
257 Mawsons Way, Newberry, SC 29108 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Oct 22, 2003: Employee burns leg while repairing steam pipe
Employee #1 was setting up to repair a leaking steam pipe. The pipe had not been blocked and bled and the valves were not locked out. A coworker turned on the v alve and steam sprayed onto the leg and foot of Employee #1. He received first, second, and a small area of third degree burns and was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $300 | $120 | Feb 24, 2004 | Closed |
| Citation 1, item 4 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $875 | $350 | Feb 24, 2004 | Closed |
| Citation 1, item 8 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $300 | $120 | Feb 24, 2004 | Closed |
| Citation 1, item 9 29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks |
Serious | $875 | $350 | Feb 24, 2004 | Closed |
| Citation 1, item 12 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Serious | $525 | $210 | Feb 24, 2004 | Closed |
| Citation 1, item 16 29 CFR 1910.219(m)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $525 | $210 | Feb 24, 2004 | Closed |
| Citation 1, item 20 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $500 | $200 | Feb 24, 2004 | Closed |
| Citation 1, item 21a 29 CFR 10012 A |
Serious | $0 | $280 | Feb 24, 2004 | Closed |
| Citation 1, item 21b 29 CFR 10012 A |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 22a 29 CFR 1910.147(c)(5)(i) · Lockout/tagout |
Serious | $0 | $350 | Feb 24, 2004 | Closed |
| Citation 1, item 22b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 22c 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 23a 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $0 | $280 | Feb 24, 2004 | Closed |
| Citation 1, item 23b 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 24a 29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $210 | Feb 24, 2004 | Closed |
| Citation 1, item 24b 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 24c 29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 25a 29 CFR 1910.304(f)(5)(vc)(3) · Grounding and circuit protection |
Serious | $0 | $120 | Feb 24, 2004 | Closed |
| Citation 1, item 25b 29 CFR 1910.304(f)(5)(vc)(5) · Grounding and circuit protection |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 1, item 25c 29 CFR 1910.304(f)(5)(vc)(7) · Grounding and circuit protection |
Serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 1 29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 2 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 3 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 4 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 5 29 CFR 1910.24(b) · Fixed industrial stairs |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 6 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 7 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
| Citation 2, item 8 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Feb 24, 2004 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Newberry site logged 2 recordable injuries or illnesses among about 159 workers: 1.1 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 2 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Kiswire, Incorporated Newberry · 2025 | 159 | 2 | 1 | 1.1 | 3.6 |
| Kiswire, Inc. Newberry · 2025 | 89 | 1 | 0 | 1.1 | 3.6 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1025(c)(1)
(c) Permissible exposure limit (PEL). (1) The employer shall assure that no employee is exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 µg/m 3) averaged over an 8-hour period.
29 CFR 1910.1025(d)(7)
(7) Additional monitoring. Whenever there has been a production, process, control or personnel change which may result in new or additional exposure to lead, or whenever the employer has any other reason to suspect a change which may result in new or additional exposures to lead, additional monitoring in accordance with this paragraph shall be conducted.
29 CFR 1910.1025(e)(1)(i)
(e) Methods of compliance—(1) Engineering and work practice controls. (i) Where any employee is exposed to lead above the permissible exposure limit for more than 30 days per year, the employer shall implement engineering and work practice controls (including administrative controls) to reduce and maintain employee exposure to lead in accordance with the implementation schedule in Table I below, except to the extent that the employer can demonstrate that such controls are not feasible. Wherever the engineering and work practice controls which can be instituted are not sufficient to reduce employee exposure to or below the permissible exposure limit, the employer shall nonetheless use them to reduce exposures to the lowest feasible level and shall supplement them by the use of respiratory protection which complies with the requirements of paragraph (f) of this section.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.