Inspection 348072638 OPENED FEB 28, 2025Closed
6439 Lansdowne Ave, Philadelphia, PA 19151 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Philadelphia, Pennsylvania · Framing Contractors · NAICS 238130
Since 2004, OSHA inspectors have visited KJMK Construction Company, Inc. in Pennsylvania 10 times.
The most recent inspection opened on Feb 28, 2025 as a planned inspection, in Philadelphia.
In all, OSHA issued 13 citation items: 10 serious, 2 repeat and 1 other-than-serious.
The proposed penalties came to $41,579; today they stand at $26,341, 37% less.
The rule cited most here is 1926.501 (fall protection in construction), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. KJMK Construction Company, Inc. averages $17,813 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
277employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch KJMK Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company6439 Lansdowne Ave, Philadelphia, PA 19151 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3226 Germantown Ave, Philadelphia, PA 19140 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2400-2455 Stewart Street, Philadelphia, PA 19121 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $10,938 | $6,563 | Feb 1, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $10,938 | $6,563 | Feb 1, 2023 | Final |
| Citation 1, item 3 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $7,813 | $4,688 | Feb 1, 2023 | Final |
Front And Brown Streets, Northern Liberties, Philadelphia, PA 19123 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $3,080 | $2,000 | Oct 1, 2012 | Closed |
| Citation 1, item 2a 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $1,760 | $1,145 | Oct 1, 2012 | Closed |
| Citation 1, item 2b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | Oct 1, 2012 | Closed |
| Citation 2, item 1 29 CFR 1904.40(a) · Giving injury records to OSHA |
Other-than-serious | $1,000 | $700 | Oct 1, 2012 | Closed |
4203 Walnut St., Philadelphia, PA 19104 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4203 Walnut St., Philadelphia, PA 19104 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1821 Spruce Street, Philadelphia, PA 19103 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $1,000 | $1,000 | Nov 29, 2007 | Closed |
| Citation 2, item 1 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Repeat | $2,000 | $2,000 | Nov 29, 2007 | Closed |
820-822 South 13th Street, Philadelphia, PA 19147 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Repeat | $2,000 | $1,000 | May 5, 2005 | Closed |
325 Diamond Street, Philadelphia, PA 19122 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
325 Diamond Street, Philadelphia, PA 19122 · Framing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $600 | $383 | Nov 9, 2004 | Closed |
| Citation 1, item 1b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | Nov 9, 2004 | Closed |
| Citation 1, item 2 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $450 | $300 | Nov 9, 2004 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.40(a)
(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(4)
(4) Ladders shall be used only for the purpose for which they were designed.