24inspections
34citation items
$71,443current penalties
Oct 16, 2023last inspection

Since 1991, OSHA inspectors have visited L&R Structural Corp., Inc. in Florida 24 times.

The most recent inspection opened on Oct 16, 2023 as part of a related case, in Miami.

In all, OSHA issued 34 citation items: 27 serious, 2 repeat and 5 other-than-serious.

The proposed penalties came to $112,473; today they stand at $71,443, 36% less.

The rule cited most here is 1926.501 (fall protection in construction), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. L&R Structural Corp., Inc. averages $7,857 across 3 cited inspections.

L&R Structural Corp., Inc. also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 2 cases on it since 2015, with $35,530 in back wages owed to workers.

L&R Structural Corp., Inc.: OSHA citation items per year, 1991 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch L&R Structural Corp., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347036139 OPENED OCT 16, 2023Closed

Unprogrammed related · Partial · Safety · 7 employees at the site · Closed Jan 30, 2024

3810 Nw 11th Street, Miami, FL 33125 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345518922 OPENED SEP 3, 2021Closed

Fatality or catastrophe · No inspection · Health · 117 employees at the site · Closed Sep 21, 2021

1 Curtis Parkway, Miami Springs, FL 33166 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343948881 OPENED APR 19, 2019Closed

Referral · Partial · Safety · 135 employees at the site · Closed Sep 16, 2019

2875 Concorde Center Drive, Aventura, FL 33180 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$11,934$8,354Aug 15, 2019Final
Citation 1, item 2a
29 CFR 1926.1411(b)(1) · Power line safety—while traveling under or near power lines with no load
Serious$11,934$8,354Aug 15, 2019Final

Inspection 343770897 OPENED FEB 7, 2019Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Aug 26, 2019

1801 S. Bearing Street, Dania Beach, FL 33004 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342054830 OPENED JAN 25, 2017Closed

Planned · Partial · Safety · 200 employees at the site · Closed Jun 9, 2017

243 Ne 3rd Street, Miami, FL 33132 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340797851 OPENED JUL 23, 2015Closed

Referral · Complete · Safety · 136 employees at the site · Closed Aug 4, 2015

10700 City Center Blvd., Pembroke Pines, FL 33026 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340499292 OPENED MAR 26, 2015Closed

Unprogrammed related · Partial · Safety · 12 employees at the site · Closed Jun 16, 2015

10700 City Center Blvd, Pembroke Pines, FL 33026 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$6,930$5,544May 12, 2015Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$6,930$0May 12, 2015Final

Inspection 340213867 OPENED JAN 28, 2015Closed

Complaint · Partial · Health · 24 employees at the site · Closed Apr 28, 2015

17475 Collins Ave, Sunny Isles Beach, FL 33160 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$1,320$1,320Mar 13, 2015Final
Citation 1, item 1b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Mar 13, 2015Final
Citation 1, item 1c
29 CFR 1910.134(h)(1) · Respiratory protection
Other-than-serious$0$0Mar 13, 2015Final
16 older inspections

Inspection 339789547 OPENED MAY 22, 2014Closed

Referral · Partial · Safety · 121 employees at the site · Closed May 22, 2014

250 Ne 25th Street, Miami, FL 33137 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339535932 OPENED DEC 30, 2013Closed

Referral · Partial · Safety · 60 employees at the site · Closed May 16, 2014

162 Nw 25th Street, Miami, FL 33137 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339424400 OPENED SEP 24, 2013Closed

Complaint · Partial · Safety · 12 employees at the site · Closed May 23, 2014

Colllins/ 174 Street, Sunny Isles Beach, FL 33160 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1428(c)(2) · Signal person qualifications
Serious$2,800$2,240Feb 10, 2014Final

Inspection 315351700 OPENED MAR 15, 2011Closed

Unprogrammed other · Partial · Safety · 31 employees at the site · Closed Dec 16, 2011

703 N Flamingo Rd, Pembroke Pines, FL 33028 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$3,850$3,850May 18, 2011Final
Citation 1, item 2a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,850$8,150May 18, 2011Final
Citation 1, item 2b
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$7,700$0May 18, 2011Final

Inspection 314269036 OPENED JAN 11, 2011Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 1, 2012

100 Burton Dr., Tavernier, FL 33070 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$7,000$3,500Jan 31, 2011Closed

Inspection 314269424 OPENED JAN 10, 2011Closed

Planned · Complete · Safety · 30 employees at the site · Closed Dec 8, 2011

703 N Flamingo Rd, Pembroke Pines, FL 33028 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314266073 OPENED OCT 8, 2010Closed

Planned · Partial · Safety · 22 employees at the site · Closed Dec 6, 2010

3176 S.w. 120th Terr., Miramar, FL 33027 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,925$1,925Dec 1, 2010Closed

Inspection 314260076 OPENED MAR 1, 2010Closed

Referral · Partial · Safety · 5 employees at the site · Closed Apr 19, 2010

7350 Davie Road Extension, Hollywood, FL 33021 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,000$2,250Apr 1, 2010Closed
Citation 1, item 2
29 CFR 1926.550(a)(1) · [Reserved]
Serious$3,000$2,250Apr 1, 2010Closed

Inspection 310215108 OPENED FEB 1, 2007Closed

Unprogrammed related · Complete · Safety · 27 employees at the site · Closed Dec 11, 2007

135 San Lorenzo Ave., Coral Gables, FL 33416 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,700$1,700Jul 9, 2007Final

Inspection 310213400 OPENED DEC 5, 2006Closed

Referral · Partial · Safety · 46 employees at the site · Closed May 22, 2008

333 Ne 24th Street, Miami, FL 33469 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$5,000$1,500Feb 1, 2007Final
Citation 1, item 2
29 CFR 1926.25(a) · Housekeeping
Serious$3,500$1,250Feb 1, 2007Final
Citation 1, item 3
29 CFR 1926.250(b)(1) · General requirements for storage
Serious$2,500$1,250Feb 1, 2007Final
Citation 1, item 5
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,000$4,000Feb 1, 2007Final
Citation 1, item 6
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,500$1,000Feb 1, 2007Final
Citation 1, item 7
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$2,000$1,000Feb 1, 2007Final

Inspection 308403013 OPENED FEB 10, 2005Closed

Referral · Partial · Safety · 13 employees at the site · Closed Apr 27, 2005

900 Sw 8 Street, Miami, FL 33130 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Feb 10, 2005: Employee is injured when struck by elevator car

At approximately 8:30 a.m. on February 10, 2005, an employee was struck on the h ead by the bottom of a hoist car after he stuck his head through an opening in t he hoistway. There was a wall opening between a guardrail and a wood form. The e mployee stuck his head through the opening between a wood form and a guardrail a nd was struck by the elevator's platform, while the car was descending. The empl oyee received bruises but was not hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,625$1,219Mar 4, 2005Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,625$1,219Mar 4, 2005Closed
Citation 1, item 3
29 CFR 1926.552(c)(1) · Material hoists, personnel hoists, and elevators
Serious$1,625$1,218Mar 4, 2005Closed

Inspection 304251473 OPENED FEB 20, 2002Closed

Planned · Complete · Safety · 20 employees at the site · Closed Dec 10, 2002

2665 Sw 37 Avenue, Miami, FL 33129 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$2,250Jun 10, 2002Closed

Inspection 304250707 OPENED FEB 4, 2002Closed

Referral · Complete · Safety · 1 employee at the site · Closed Mar 11, 2002

Nw 36 Street And Nw 62 Avenue, Miami, FL 33166 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$2,250Feb 19, 2002Closed

Inspection 301883146 OPENED MAR 31, 1999Closed

Unprogrammed related · Complete · Safety · 80 employees at the site · Closed Jun 8, 1999

703 N Flamingo Rd, Pembroke Pines, FL 33028 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,575$1,075May 4, 1999Closed
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$900$600May 4, 1999Closed

Inspection 301883427 OPENED MAR 19, 1999Closed

Unprogrammed other · Complete · Safety · 80 employees at the site · Closed Jun 8, 1999

155 Ocean Drive, Miami Beach, FL 33178 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,050May 3, 1999Closed

Inspection 106115231 OPENED AUG 12, 1991Closed

Unprogrammed related · Complete · Safety · 8 employees at the site · Closed Nov 25, 1991

Sw 9th St. & Flagler St., Miami, FL 33130 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Oct 3, 1991Closed
Citation 1, item 1b
29 CFR 1926.451(g)(3) · Scaffolds, general requirements
Serious$0$0Oct 3, 1991Closed
Citation 1, item 1c
29 CFR 1926.451(g)(5) · Scaffolds, general requirements
Serious$0$0Oct 3, 1991Closed
Citation 1, item 2
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$750$375Oct 3, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Miami site logged 0 recordable injuries or illnesses among about 157 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
L&R Structural Corp. Inc.
Miami · 2025
157 000.02.8
L&R Structural Corp Inc.
Miami · 2022
153 100.82.8
L&R Structural Corp., Inc
Miami · 2020
162 331.92.8
L&R Structural
Miami · 2019
170 1359.32.8

Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Aug 18, 2016 to Aug 17, 2018
Miami
108$27,358$0
Aug 1, 2014 to Mar 30, 2015
Miami
52$8,172$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.134(h)(1)

(1) Cleaning and disinfecting. The employer shall provide each respirator user with a respirator that is clean, sanitary, and in good working order. The employer shall ensure that respirators are cleaned and disinfected using the procedures in appendix B-2 of this section, or procedures recommended by the respirator manufacturer, provided that such procedures are of equivalent effectiveness. The respirators shall be cleaned and disinfected at the following intervals:

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1411 · Power line safety—while traveling under or near power lines with no load

29 CFR 1926.1428 · Signal person qualifications

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.25 · Housekeeping

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.550 · [Reserved]

29 CFR 1926.552 · Material hoists, personnel hoists, and elevators

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Florida