OSHA SearchOSHA records by employer

L2 Excavation LLC: OSHA inspections and violations

Boise, Idaho · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
5citation items
$29,906current penalties
Jun 21, 2023last inspection

L2 Excavation LLC has 4 OSHA inspections on record in Idaho, the first in 2018.

OSHA's last visit started on Jun 21, 2023 after a complaint, in Boise.

Across those inspections OSHA issued 5 citation items: 1 serious and 4 other-than-serious.

OSHA proposed $32,860 in penalties. After settlements and reviews the total is $29,906, down 9%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. L2 Excavation LLC averages $14,953 over 2 cited inspections in that time.

L2 Excavation LLC: OSHA citation items per year, 2018 to 2023
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

61employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch L2 Excavation LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346783178 OPENED JUN 21, 2023Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Sep 20, 2023

N. Turret Way, Boise, ID 83703 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346576028 OPENED MAR 15, 2023Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 25, 2023

Linder Rd At Columbia Rd, Kuna, ID 83634 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$9,844$9,844Jul 26, 2023Final
Citation 1, item 2
29 CFR 1926.651(h) · Excavations
Other-than-serious$9,844$9,844Jul 26, 2023Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$9,844$6,890Jul 26, 2023Final

Inspection 345825418 OPENED MAR 9, 2022Closed

Referral · Partial · Safety · 4 employees at the site · Closed May 6, 2022

Ten Mile Road And Val Vista, Meridian, ID 83642 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$3,328$3,328Apr 21, 2022Final
Citation 1, item 1b
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Apr 21, 2022Final

Inspection 342987997 OPENED FEB 20, 2018Closed

Referral · Partial · Safety · 4 employees at the site · Closed Mar 8, 2018

Cloverdale Rd And Bowmont Rd, Boise, ID 83213 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

Other water and sewer line and related structures construction employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.