OSHA SearchOSHA records by employer

Lawrence Companies, Inc.: OSHA inspections and violations

Roanoke, Virginia · Used Household and Office Goods Moving · NAICS 484210

3inspections
9citation items
$17,542current penalties
Mar 25, 2026last inspection

OSHA has inspected Lawrence Companies, Inc. 3 times in Virginia since 2024.

The latest one began on Mar 25, 2026 after a fatality or catastrophe, in Disputanta.

Those inspections ended with 9 citation items: 8 serious and 1 other-than-serious.

Penalties were first proposed at $25,060 and now stand at $17,542, 30% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $2,416, and Lawrence Companies, Inc. averages $17,542 (1 cited inspection).

Lawrence Companies, Inc.: OSHA citation items per year, 2024 to 2026
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Lawrence Companies, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348840844 OPENED MAR 25, 2026Closed

Fatality or catastrophe · Partial · Safety · 137 employees at the site · Closed Aug 5, 2026

5310 W. Quaker Road, Disputanta, VA 23842 · Used Household and Office Goods Moving · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347427569 OPENED APR 19, 2024Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 16, 2024

Hotel Roanoke 110 Shenandoah Ave, Roanoke, VA 24016 · Used Household and Office Goods Moving · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347357097 OPENED MAR 20, 2024Closed

Planned · Complete · Health · 300 employees at the site · Closed May 28, 2024

872 Lee Highway, Roanoke, VA 24019 · General Freight Trucking, Local · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$9,745$6,822Apr 26, 2024Final
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Apr 26, 2024Final
Citation 1, item 1c
29 CFR 1910.107(g)(3) · Spray painting and finishing
Serious$0$0Apr 26, 2024Final
Citation 1, item 2
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Serious$5,105$3,574Apr 26, 2024Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,105$3,574Apr 26, 2024Final
Citation 1, item 3b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Apr 26, 2024Final
Citation 1, item 3c
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Apr 26, 2024Final
Citation 1, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$5,105$3,574Apr 26, 2024Final
Citation 2, item 1
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Apr 26, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(g)(3)

(3) Residue disposal. Residue scrapings and debris contaminated with residue shall be immediately removed from the premises and properly disposed of. Approved metal waste cans shall be provided wherever rags or waste are impregnated with finishing material and all such rags or waste deposited therein immediately after use. The contents of waste cans shall be properly disposed of at least once daily or at the end of each shift.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.215 · Grinders and abrasive wheels

Other used household and office goods moving employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.