OSHA SearchOSHA records by employer

LFM Industries Inc.: OSHA inspections and violations

Houston, Texas · Machine Shops · NAICS 332710

2inspections
11citation items
$10,469current penalties
Jul 27, 2018last inspection

OSHA has inspected LFM Industries Inc. 2 times in Texas since 2015.

The latest one began on Jul 27, 2018 after a complaint, in Houston.

Those inspections ended with 11 citation items: 9 serious and 2 other-than-serious.

Penalties were first proposed at $20,077 and now stand at $10,469, 48% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and LFM Industries Inc. averages $5,234 (2 cited inspections).

LFM Industries Inc.: OSHA citation items per year, 2015 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch LFM Industries Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343336020 OPENED JUL 27, 2018Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jan 26, 2026

117 N. Palmer, Houston, TX 77251 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,696$2,218Nov 15, 2018Final
Citation 1, item 1b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Nov 15, 2018Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,217$1,330Nov 15, 2018Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Nov 15, 2018Final
Citation 1, item 3
29 CFR 1910.179(j)(1)(ii)(b) · Overhead and gantry cranes
Serious$2,956$1,774Nov 15, 2018Final
Citation 1, item 4
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$3,696$0Nov 15, 2018Final
Citation 1, item 5a
29 CFR 1910.303(c)(3)(i) · Electrical equipment, general requirements
Serious$2,956$1,774Nov 15, 2018Final
Citation 1, item 5b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Nov 15, 2018Final
Citation 1, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$2,956$1,774Nov 15, 2018Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 15, 2018Final

Inspection 341145357 OPENED DEC 29, 2015Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jul 16, 2019

117 N. Palmer, Houston, TX 77251 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$1,600$1,600Apr 7, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

Other machine shops employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.