OSHA SearchOSHA records by employer

Liberty Display Group Inc: OSHA inspections and violations

Blaine, Minnesota · All Other Plastics Product Manufacturing · NAICS 326199

8inspections
8citation items
$469current penalties
Mar 5, 2019last inspection

Liberty Display Group Inc has 8 OSHA inspections on record in Minnesota, the first in 1992.

OSHA's last visit started on Mar 5, 2019 as a planned inspection, in Minneapolis.

Across those inspections OSHA issued 8 citation items: 1 serious and 7 other-than-serious.

OSHA proposed $574 in penalties. After settlements and reviews the total is $469, down 18%.

Most often, OSHA cited 5206.700, (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Liberty Display Group Inc averages $105 over 1 cited inspection in that time.

Liberty Display Group Inc: OSHA citation items per year, 1992 to 2019
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Liberty Display Group Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343837845 OPENED MAR 5, 2019Closed

Planned · Complete · Health · 12 employees at the site · Closed Mar 21, 2019

10087 Goodhue St Ne, Minneapolis, MN 55449 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341151918 OPENED DEC 8, 2015Closed

Planned · Complete · Health · 11 employees at the site · Closed Jan 4, 2016

10087 Goodhue St Ne, Minneapolis, MN 55449 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$150$105Dec 18, 2015Final

Inspection 317018380 OPENED MAR 14, 2013Closed

Planned · Complete · Safety · 11 employees at the site · Closed Apr 29, 2013

10087 Goodhue St Ne, Blaine, MN 55449 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$100$70Apr 2, 2013Closed

Inspection 314461906 OPENED MAY 10, 2010Closed

Planned · Complete · Health · 12 employees at the site · Closed May 14, 2010

10087 Goodhue St Ne, Blaine, MN 55449 · Showcase, Partition, Shelving, and Locker Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309390367 OPENED AUG 25, 2005Closed

Planned · Complete · Health · 25 employees at the site · Closed Aug 26, 2005

10087 Goodhue St Ne, Blaine, MN 55449 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302091202 OPENED JUL 1, 1998Closed

Planned · Complete · Safety · 21 employees at the site · Closed Jul 1, 1998

10087 Goodhue St Ne, Blaine, MN 55449 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126569532 OPENED JUN 19, 1995Closed

Planned · Complete · Health · 22 employees at the site · Closed Jul 28, 1995

10087 Goodhue St Ne, Blaine, MN 55449 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$100$70Jul 11, 1995Closed

Inspection 120437967 OPENED SEP 15, 1992Closed

Planned · Complete · Safety · 20 employees at the site · Closed Apr 19, 1993

10087 Goodhue St Ne, Blaine, MN 55449 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(3) · Guarding floor and wall openings and holes
Other-than-serious$0$0Oct 1, 1992Closed
Citation 1, item 2 Other-than-serious$0$0Oct 1, 1992Closed
Citation 1, item 3
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Oct 1, 1992Closed
Citation 1, item 4 Other-than-serious$84$84Oct 1, 1992Closed
Citation 1, item 5 Other-than-serious$140$140Oct 1, 1992Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1910.95 · Noise

29 CFR 1910.95(c)(1)

(c) Hearing conservation program. (1) The employer shall administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent. For purposes of the hearing conservation program, employee noise exposures shall be computed in accordance with appendix A and Table G-16a, and without regard to any attenuation provided by the use of personal protective equipment.

29 CFR 5205.116

29 CFR 5206.700

29 CFR 5210.630

Other all other plastics product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.